Order No
101181059
Article Code
101181059
Certificates
cULus
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
CSS 14-34-S-D-M-L
Product Description
- • IP Rating: IP65/IP67 | Weight: 295 g | Cable: 1 m | Certification: cULus | PL e
Standards
- • EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508
Product Features
- • 1 x Pre-wired cable 8-pole_x000D_
- • Yandan aktüasyon_x000D_
- • Max. 31 sensors can be wired in series._x000D_
- • Termoplastik gövde_x000D_
- • Elektronik temazsız kodlu sistem_x000D_
- • Misaligned actuation possible_x000D_
- • 27 mm x 108.2 mm x 35 mm_x000D_
- • High repeat accuracy of the switching points_x000D_
- • Sensör zincirinin maks. uzunluğu 200 m_x000D_
- • 2 short-circuit proof PNP safety outputs_x000D_
- • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Technical Specifications
PIN 1
A1 Ue Brown
PIN 2
X1 Safety input 1 White
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black
PIN 5
OUTPUT Diagnostics output OUT Grey
PIN 6
X2 Safety input 2 violet
PIN 7
Y2 Safety output 2 red
PIN 8
Fonksiyonsuz INPUT Pembe
Category
4
General Note
Evaluation gereksinimleri: dual channel safety input, NA fonksiyonlu p-type sensor for suitable. Safety monitoring module sensor exit maks.
Active Area
Yanal
Cable Type
LiYY
Wire Cross-Section
22 AWG
PFH Value
3.60 x 10⁻⁹ /h
Number of LEDs
3
Impact Resistance
30 g / 11 ms
EMC Class
IEC 61000-6-2
Mission Time
20 Year(s)
Max. Hysteresis
1.5 mm
Cable Length
1 m
Gross Weight
295 g
Housing Material
Cam elyaf takviyeli termoplastik
Protection Class
II
Pollution Degree
3
Radiated Interference
IEC 61000-6-4
Sensor Length
35 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Max. Cable Cross-Section
8 x 0.35 mm²
Max. Risk Time
60 ms
Sensor Topology
Series connection for sensor
Operating Current
600 mA
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
30 ms
Ambient Temperature
-25 ... +70 °C
Performance Level
e
Sensor Width
27 mm
Operating Principle
inductive
Actuation Panels
Yanal
Cascadable
Yes
Housing Design Form
Blok
Sensor Height
108.2 mm
Recommendation (Actuator)
CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2 CST 34-S-1
Repeat Accuracy R
0.5 mm
Diagnostic Output
Yes
Cross-Circuit Detection
Yes
Terminal Connection
Cable (Y-UL 2517), 8 pole
Max. Leakage Current (Ir)
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Current Utilization Cat. DC-12
0.05 A
Current Utilization Cat. DC-13
0.05 A
Utilization Category DC-12
24 VDC / 0.05 A
Mechanical Mounting Conditions
Embedded not
Note (Repeat Accuracy R)
Axial offset: the long edge allows a maximum height misalignment of 36 mm between the sensor and the actuator. With the CST 34-S-2 actuator, an increased misalignment of max. 53 mm is possible. Axial misalignment (y) max. ±10 mm.
Overvoltage Category
III
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Max. Voltage Drop (Ud)
5 V
Number of Sensors Connected in Series
31
Impulse Withstand Voltage (Uimp)
0.8 kV
Control Elements Design
p-tipi
Actuator Switching Distance
Actuator CST 34-V-1: 10 mm (typical switch distance Sn); Actuator CST 34-V-1: 8 mm (ensured switch distance ON Sao); Actuator CST 34-V-1: 13 mm (ensured switch distance OFF Sar); Actuator CST 34-S-1 / CST 34-S-3: 14 mm (typical switch distance Sn); Actuator CST 34-S-1 / CST 34-S-3: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-1 / CST 34-S-3: 17 mm (ensured switch distance OFF Sar); Actuator CST 34-S-2: 14 mm (typical switch distance Sn); Actuator CST 34-S-2: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-2: 17 mm (ensured switch distance OFF Sar); Actuator CST 180-1 / CST 180-2: 10 mm (typical switch distance Sn); Actuator CST 180-1 / CST 180-2: 8 mm (ensured switch distance ON Sao); Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar)
Storage/Transport Temperature
-25 ... +85 °C
Integrated System Diagnostics Status
Yes
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Approximate Switching Frequency
3 Hz
Rated Insulation Voltage (Uᵢ)
32 VDC
Required Rated Short-Circuit Current
100 A
Number of Safe Digital Outputs
2
Typical Idle Operating Current (I₀)
100 mA
Max. Output Current (Safe Output)
0.25 A
Number of Semiconductor Outputs with Signal Function
1
Rated Operating Current (Safety Outputs)
250 mA