Order No
101181066
Certificates
cULus
Schmersal
System Solutions
Series Diagnostic Systems
CSS 14-34-S-SD-M-ST Series Diagnostic Systems
Schmersal CSS 14-34-S-SD-M-ST features inductive working principle, cam elyaf takviyeli termoplastik housing material, IP65 IP67 protection class and -25 ... +70 °C ambient temperature.
Product Description
- • IP Rating: IP65/IP67
- • Weight: 140 g
- • Certification: cULus
- • PL e
Standards
- • EN ISO 13849-1
- • EN IEC 60947-5-3
- • EN IEC 61508
Product Features
- • 1 x connector plug M12, 8-pole
- • Actuation from the side
- • serial diagnostic output
- • Max. 31 sensors can be wired in series.
- • Thermoplastic housing
- • Electronic non-contact coded system
- • Misaligned actuation possible
- • 27 mm x 108.2 mm x 35 mm
- • High repeat accuracy of the switching points
- • Max. length of the sensor chain 200 m
- • 2 short-circuit proof PNP safety outputs
- • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Technical Specifications
PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
SD serial diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
INPUT serial diagnostic input
Category
4
General note
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety monitoring module must tolerate max. ... of the sensor outputs.
Active Area
Lateral
PFH value
3.60 x 10⁻⁹ /h
Number of LEDs
3
Shock resistance
30 g / 11 ms
EMC Class
IEC 61000-6-2
Mission time
20 Year(s)
Max. Hysteresis
1.5 mm
Serial Diagnostics
Yes
Gross weight
140 g
Housing Material
Glass-fibre reinforced thermoplastic
Protection Class
II
Pollution degree
3
Radiated Interference
IEC 61000-6-4
Sensor length
35 mm
Scope of delivery
Actuator must be ordered separately.
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Cable Capacitance
50 nF
Max. Risk Time
60 ms
Sensor Topology
Sensor for series connection
Operating current
150 mA
IP protection class
IP65 IP67
Short-Circuit Detection
Yes
Max. reaction time
30 ms
Ambient Temperature
-25 ... +70 °C
Performance level
e
Sensor width
27 mm
Working Principle
inductive
Actuation Panels
Lateral
Cascadable
Yes
Housing Design
Block
Sensor height
108.2 mm
Recommendation (Actuator)
CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2 CST 34-S-1
Repeat Accuracy R
0.5 mm
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output
Yes
Cross-Circuit Detection
Yes
Terminal connection
M12 connector plug, 8-pole
Max. Leakage Current (Ir)
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Current Utilization Cat. DC-12
0.25 A
Current Utilization Cat. DC-13
0.25 A
Mechanical Mounting Conditions
Non-flush
Note (Repeat Accuracy R)
Axial offset: the long edge allows a maximum height misalignment of 36 mm between the sensor and the actuator. With the CST 34-S-2 actuator, an increased misalignment of max. 53 mm is possible. Axial misalignment (y) max. ±10 mm.
Overvoltage category
III
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Serial Diagnostics (SD) Definition
OUT
Max. Voltage Drop (Ud)
5 V
Number of Sensors Connected in Series
31
Rated impulse withstand voltage (Uimp)
0.8 kV
Control Elements Design
Short-circuit proof, p-type
Actuator Switching Distance
Actuator CST 34-V-1: 10 mm (typical switch distance Sn); Actuator CST 34-V-1: 8 mm (ensured switch distance ON Sao); Actuator CST 34-V-1: 13 mm (ensured switch distance OFF Sar); Actuator CST 34-S-1 / CST 34-S-3: 14 mm (typical switch distance Sn); Actuator CST 34-S-1 / CST 34-S-3: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-1 / CST 34-S-3: 17 mm (ensured switch distance OFF Sar); Actuator CST 34-S-2: 14 mm (typical switch distance Sn); Actuator CST 34-S-2: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-2: 17 mm (ensured switch distance OFF Sar); Actuator CST 180-1 / CST 180-2: 10 mm (typical switch distance Sn); Actuator CST 180-1 / CST 180-2: 8 mm (ensured switch distance ON Sao); Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar)
Storage/transport temperature
-25 ... +85 °C
Integrated System Diagnostics Status
Yes
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Approximate Switching Frequency
3 Hz
Rated insulation voltage (Uᵢ)
32 VDC
Required rated short-circuit current
100A
Number of Safe Digital Outputs
2
Note (Electrical Data Fuse Rating)
(Circuit breaker)
Typical Idle Operating Current (I₀)
100 mA
Max. Output Current (Safe Output)
0.25 A
Number of Semiconductor Outputs with Signal Function
1
Rated Operating Current (Safety Outputs)
250 mA