CSS 14-34F1-S-D-M-ST
Order No 101189087
Article Code 101189087
Certificates cULus
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

CSS 14-34F1-S-D-M-ST

Product Description

  • • IP Rating: IP65/IP67 | Weight: 141 g | Certification: cULus | PL e

Standards

  • • EN ISO 13849-1 EN IEC 60947-5-3 EN IEC 61508

Product Features

  • • 1 x connector plug M12, 8-pole_x000D_
  • • Yandan aktüasyon_x000D_
  • • with edge monitoring of the reset pushbutton_x000D_
  • • To control positive-guided relay without downstream safety monitoring module_x000D_
  • • Suitable as individual or terminal device in series-wiring of standards sensors to replace a safety monitoring module_x000D_
  • • Self-monitored series-wiring of up to 30 CSS 34 sensors and one CSS 34F0/F1 sensor for control category 4 to ISO 13849-1_x000D_
  • • Termoplastik gövde_x000D_
  • • Elektronik temazsız kodlu sistem_x000D_
  • • Misaligned actuation possible_x000D_
  • • 27 mm x 108.2 mm x 35 mm_x000D_
  • • High repeat accuracy of the switching points_x000D_
  • • Sensör zincirinin maks. uzunluğu 200 m_x000D_
  • • 2 short-circuit proof PNP safety outputs_x000D_
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Technical Specifications

PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 OUTPUT Diagnostics output OUT
PIN 6 X2 Safety input 2
PIN 7 Y2 Safety output 2
PIN 8 Fonksiyonsuz INPUT
Category 4
General Note Evaluation gereksinimleri: dual channel safety input, NA fonksiyonlu p-type sensor for suitable. Safety monitoring module sensor exit maks.
Active Area Yanal
PFH Value 3.60 x 10⁻⁹ /h
Number of LEDs 3
Impact Resistance 30 g / 11 ms
EMC Class IEC 61000-6-2
Mission Time 20 Year(s)
Max. Hysteresis 1.5 mm
Gross Weight 141 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class II
Pollution Degree 3
Radiated Interference IEC 61000-6-4
Sensor Length 35 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Risk Time 60 ms
Sensor Topology Series connection for sensor
Operating Current 600 mA
IP Protection Class IP65 IP67
Short-Circuit Detection Yes
Max. Response Time 30 ms
Ambient Temperature -25 ... +70 °C
Performance Level e
Sensor Width 27 mm
Operating Principle inductive
Actuation Panels Yanal
Cascadable Yes
Housing Design Form Blok
Sensor Height 108.2 mm
Recommendation (Actuator) CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2 CST 34-S-1
Repeat Accuracy R 0.5 mm
Diagnostic Output Yes
Cross-Circuit Detection Yes
Terminal Connection M12 connector plug, 8 pole
Max. Leakage Current (Ir) 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Mechanical Mounting Conditions Embedded not
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment of 36 mm between the sensor and the actuator. With the CST 34-S-2 actuator, an increased misalignment of max. 53 mm is possible. Axial misalignment (y) max. ±10 mm.
Overvoltage Category III
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Max. Voltage Drop (Ud) 5 V
Number of Sensors Connected in Series 31
Impulse Withstand Voltage (Uimp) 0.8 kV
Control Elements Design p-tipi
Actuator Switching Distance Actuator CST 34-V-1: 10 mm (typical switch distance Sn); Actuator CST 34-V-1: 8 mm (ensured switch distance ON Sao); Actuator CST 34-V-1: 13 mm (ensured switch distance OFF Sar); Actuator CST 34-S-1 / CST 34-S-3: 14 mm (typical switch distance Sn); Actuator CST 34-S-1 / CST 34-S-3: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-1 / CST 34-S-3: 17 mm (ensured switch distance OFF Sar); Actuator CST 34-S-2: 14 mm (typical switch distance Sn); Actuator CST 34-S-2: 12 mm (ensured switch distance ON Sao); Actuator CST 34-S-2: 17 mm (ensured switch distance OFF Sar); Actuator CST 180-1 / CST 180-2: 10 mm (typical switch distance Sn); Actuator CST 180-1 / CST 180-2: 8 mm (ensured switch distance ON Sao); Actuator CST 180-1 / CST 180-2: 13 mm (ensured switch distance OFF Sar)
Storage/Transport Temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Approximate Switching Frequency 3 Hz
Rated Insulation Voltage (Uᵢ) 32 VDC
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
Edge-Monitored Reset Button Input Yes
Note (Electrical Data Fuse Rating) (Circuit breaker)
Typical Idle Operating Current (I₀) 100 mA
Max. Output Current (Safe Output) 0.25 A
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 250 mA
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.