CSS 8-16-2P-E-L
Order No 101210574
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

CSS 8-16-2P-E-L

CSS 8-16-2P-E-L — Schmersal product. Key specifications: Working Principle: inductive; IP protection class: IP67 | IP65; Ambient Temperature: -25 ... +55 °C; Sensor length: 39.5 mm; Sensor width: 55 mm. Article number: 101210574. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 315 g
  • • Sertifika: cULus

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN ISO 13849-1

Product Features

  • • Pre-wired cable 4-pole
  • • NOTICE: Not available! (Replacement: RSS16)
  • • Thermoplastic enclosure
  • • Electronic contact-free, coded system
  • • Misaligned actuation possible
  • • 55 mm x 93 mm x 39.5 mm
  • • High repeat accuracy of the switching points
  • • Max. length of the sensor chain 200 m
  • • Early warning when operating near the limit of the sensor's hysteris range
  • • Self-monitoring series-wiring of 16 sensors
  • • 2 short-circuit proof PNP safety outputs

Technical Specifications

PIN 1 A1 Ue Brown
PIN 2 Y2 safety output 2: White
PIN 3 A2 GND Blue
PIN 4 Y1 Safety output 1 Black
Category 4
General note Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circ
PFH value 2.50 x 10⁻⁹ /h
EMC rating IEC 61000-6-2
Traceparts Yes
Active area Glass-fibre, reinforced thermoplastic
Voltage type DC
Shock resistance 30 g / 11 ms
Mission time 20 Year(s)
Net Ağırlık 315 g
Bağlantı Tipi cable
Length of cable 2 m
Sensor topology Individual sensor or end sensor in a series
Gross weight 315 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection class II
Safety functions Yes
Pollution degree 3
Operating voltage 24 VDC -15 % / +10 %
Repeat accuracy R 0.5 mm
Scope of delivery Actuator must be ordered separately.
Sensor length 39.5 mm
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Wire cross-section 0.5 mm² | 20 AWG
Operating current 1,100 mA
IP protection class IP67 | IP65
Ambient Temperature -25 ... +55 °C
Performance level e
Sensor width 55 mm
Working Principle inductive
Sensor height 93 mm
Interfering radiation IEC 61000-6-4
Reaction time, maximum 30 ms
Cross-circuit detection Yes
Short circuit detection Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Switch distance, typical 8 mm
Voltage drop Ud, maximum 0.5 V | 4 V
Duration of risk, maximum 30 ms
Housing construction form Block
Maks. Ortam Sıcaklığı +55 °C
Note (switching distance) All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator) CST 16-1
Design of control elements p-type
Utilization Category DC-13 24 VDC / 0.5 A
Mechanical Mounting Conditions not flush
Terminal connector, Output 4-pole
Utilisation category DC-12 24_0.5 | 24 VDC / 0.5 A | 24 VDC / 0.05 A
Overvoltage category 3 | III
Leakage current Ir, maximum 0.5 mA
Nominal Çalışma Voltajı 24 VDC
Note (Characteristic curve) Soff: Switch-off distance | S: switching distance | V: Axial misalignment | Sao: Assured switching distance ON | Son: Switch-on distance | Sh: Hysteresis area | Sar: Ensured switch distance "OFF"
Switching frequency, approx. 3 Hz
Recommended safety switchgear SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Rated impulse withstand voltage (Uimp) 0.8 kV
Rated operating voltage, maximum 26.4 V
Rated operating voltage, minimum 20.4 V
Absicherung des Diagnoseausganges short-circuit proof
Depolama / Taşıma Sıcaklığı -40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ) 32 VDC
Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical 50 mA
Number of series-wiring of sensors 16
Assured switching distance "ON" Sao 6 mm
Current, Utilisation category DC-12 0.5 A
Current, Utilisation category DC-13 0.5 A
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Voltage, Utilisation category DC-12 24 VDC
Voltage, Utilisation category DC-13 24 VDC
Absicherung des Sicherheitsausganges short-circuit proof
Assured switching distance "OFF" Sar 11 mm
Protection class (Operating resource) 2
Coding level according to EN ISO 14119 Low
Note (LED switching conditions display) Multi-coloured LED: Green, Red, Yellow
Hysteresis (Switching distance), maximum 1 mm
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -25 °C
Output current, (fail-safe output), maximum 0.5 A
Safety Integrity Level (SIL), suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3