PIN 1
1A1 Ue: (1)
PIN 2
Y2 Safety output 2
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
Signalling output
Category
4
General note
Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circ
PFH value
2.50 x 10⁻⁹ /h
EMC rating
IEC 61000-6-2
Traceparts
Yes
Active area
Glass-fibre, reinforced thermoplastic
Voltage type
DC
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Net Ağırlık
115 g
Bağlantı Tipi
Cable with connector
Length of cable
2 m
Sensor topology
Individual sensor or end sensor in a series
Gross weight
115 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection class
II
Safety functions
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 %
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
39.5 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Operating current
1,100 mA
IP protection class
IP67 | IP65
Ambient Temperature
-25 ... +55 °C
Performance level
e
Sensor width
55 mm
Working Principle
inductive
Sensor height
93 mm
Interfering radiation
IEC 61000-6-4
Reaction time, maximum
30 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Switch distance, typical
8 mm
Voltage drop Ud, maximum
0.5 V | 4 V
Duration of risk, maximum
30 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+55 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
CST 16-1
Design of control elements
p-type
Utilization Category DC-13
24 VDC / 0.5 A | 24_0.05
Mechanical Mounting Conditions
not flush
Terminal connector, Output
M12 connector, 5 pole
Utilisation category DC-12
24_0.5 | 24 VDC / 0.5 A | 24 VDC / 0.05 A | 24_0.05
Overvoltage category
3 | III
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Note (Characteristic curve)
Soff: Switch-off distance | S: switching distance | V: Axial misalignment | Sao: Assured switching distance ON | Son: Switch-on distance | Sh: Hysteresis area | Sar: Ensured switch distance "OFF"
Switching frequency, approx.
3 Hz
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Rated impulse withstand voltage (Uimp)
0.8 kV
Rated operating voltage, maximum
26.4 V
Rated operating voltage, minimum
20.4 V
Absicherung des Diagnoseausganges
short-circuit proof
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C | -25 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
50 mA
Number of series-wiring of sensors
16
Assured switching distance "ON" Sao
6 mm
Current, Utilisation category DC-12
0.05 A | 0.5 A
Current, Utilisation category DC-13
0.05 A | 0.5 A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof
Assured switching distance "OFF" Sar
11 mm
Protection class (Operating resource)
2
Coding level according to EN ISO 14119
Low
Note (LED switching conditions display)
Multi-coloured LED: Green, Red, Yellow
Hysteresis (Switching distance), maximum
1 mm
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.5 A
Number of semi-conductor outputs with signaling function
1
Safety Integrity Level (SIL), suitable for applications in
3