EX-AZM 161SK-12/12RKA-3D
Order No 103055347
Certificates CCC-EX, ATEX (Konformitätserklärung) CCC-EX
Schmersal Ex / ATEX Anahtarlama Cihazları Solenoid Interlocks

EX-AZM 161SK-12/12RKA-3D Solenoid Interlocks

EX-AZM 161SK-12/12RKA-3D — Schmersal Solenoid Interlocks. Key specifications: Working Principle: electromechanical; Switching principle: slow action, positive break NC contact; Switching element: NO contact, NC contact; IP protection class: IP67; Ambient Temperature: -10 ... +50 °C. Article number: 103055347. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 1,882 g
  • • Sertifika: CCC-EX, ATEX (Konformitätserklärung) CCC-EX

Standards

  • • EN IEC 60947-5-1
  • • EN ISO 13849-1
  • • EN ISO 14119

Product Features

  • • Screw connection
  • • Ex-Zone 22
  • • Clamping force 2000N
  • • 6 Contacts
  • • Interlock with protection against incorrect locking.
  • • cable entries 4 M 16 x 1.5

Technical Specifications

Note All indications including the conductor ferrules. | Electrical life on request. | The tightening sequence of the cover screws must be observed. This can be found in the attached drawing in the “Pictures” tab. | for 2-channel use and with suitable logic unit.
Mounting Screws
CADENAS Yes
Length 40 mm
Category 3 | 1
Width 278 mm
Traceparts Yes
Height 122 mm
Cable Cross-Section 1 mm² ... 1 mm²(All indications including the conductor ferrules.) | 1 x 0.75 mm² ... 1 x 1.5 mm² (All indications including the conductor ferrules.)
Please note: Can be used when fault exclusion for dangerous damage to the 1-channel mechanism is permissible and sufficient protection against manipulation is guaranteed.
Power to lock Yes
Mission time 20 Year(s)
Latching force 30 N | 5 / 30 N
Manual release Yes
Net Ağırlık 1,882 g
Bağlantı Tipi Screw terminals
Gross weight 1,882 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Contact material Silver
Min. cable cross-section 1 x 0.75 mm²
Scope of delivery Actuator must be ordered separately. | The protective housing is included in the scope of delivery. | Including Ex-certified screwed cable gland and screw plug
Max. cable cross-section 1 x 1.5 mm²
IP protection class IP67
Ambient Temperature -10 ... +50 °C
Performance level c | d
Conventional thermal current 6 A
Working Principle electromechanical
Switching element NO contact, NC contact
Switching principle slow action, positive break NC contact
Mechanical life (min.) 1,000,000
Utilisation category DC-13
Magnet switch-on time 100 %
Maks. Sigorta Değeri 6 A gG D-fuse
Note (Manual release) For maintenance, installation, etc. | For manual release using M5 triangular key, available as accessory
Positive break travel 10 mm
Rated control voltage 24 VDC | 24 VAC
Impact energy, maximum 7 J
Traceparts, product ID 33-22052019-077196
Type of the screw head Flat head screw
Max. actuating speed 1 m/s
Min. Ortam Sıcaklığı -10 °C
Note (Relative humidity) non-condensing | non-icing
Number of safety contacts 4
Maks. Ortam Sıcaklığı +50 °C
Type of the fixing screws 3x M6
Explosion protection zones 22
Utilization Category DC-13 24 VDC / 4 A | 24 VDC / 2.5 A | 24_2.5 | 24 VDC | 2.5 A
Number of auxiliary contacts 2
Holding force Fmax, maximum 2,600 N
Max. switching frequency 1,000 /h
Test pulse duration, maximum 5 ms
Test pulse interval, minimum 50 ms
Explosion protection category 3D
Note (application conditions) removable guard | hinged safety guard | sliding safety guard
Rated impulse withstand voltage (Uimp) 4 kV
Number of actuating directions 3
B10D Normally-open contact (NO) 1,000,000
Explosion protection designation D II 3D Ex tc IIIC T80°C Dc X
B10D Normally-closed contact (NC) 2,000,000
Depolama / Taşıma Sıcaklığı -10 ... +50 °C
Explosion protection: regulations EN IEC 60079-0 | EN 60079-31
Rated insulation voltage (Uᵢ) 250 VAC
Current, Utilisation category DC-13 2.5 A
Required rated short-circuit current 1,000 A
Voltage, Utilisation category DC-13 24 VDC
Tightening torque of the cable gland 3 Nm
Electrical power consumption, maximum 10 W
Coding level according to EN ISO 14119 Low
Cable cross-section of the cable glands 5 ... 10 mm
Actuating play in direction of actuation 5.5 mm
Positive break force per NC contact, minimum 10 N
Cable cross-section of the cable glands, maximum 10 mm
Cable cross-section of the cable glands, minimum 5 mm
Holding force FZh in accordance with EN ISO 14119 2,000 N
Tightening torque of the fastening screws for the housing cover 0.6 Nm

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3