EX-BNS 33-11Z-3GD 10M
Order No 103050098
Certificates ATEX (Declaration of Conformity)
Schmersal Ex / ATEX Anahtarlama Cihazları Safety Sensors

EX-BNS 33-11Z-3GD 10M Safety Sensors

EX-BNS 33-11Z-3GD 10M — Schmersal Safety Sensors. Key specifications: Switching principle: Reed contacts, Non-contact principle; Switching element: 1 NO contact, 1 NC contacts; Housing Material: Glass-fibre, reinforced thermoplastic; IP protection class: IP67; Sensor length: 13 mm. Article number: 103050098. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 452 g
  • • Sertifika: ATEX (Konformitätserklärung)

Standards

  • • EN IEC 60947-5-3
  • • EN ISO 13849-1

Product Features

  • • Explosion protection for ATEX Zones 2 and 22
  • • Thermoplastic enclosure
  • • 88 mm x 25 mm x 13 mm
  • • Concealed mounting possible
  • • Insensitive to transverse misalignment
  • • no mechanical wear

Technical Specifications

Coding Yes
CADENAS Yes
General note The contact configuration for versions with or without LED is identical. | Contact symbols shown for the closed condition of the guard device.
Traceparts Yes
Active area lateral
Shock resistance 30 g / 11 ms
Mission time 20 Year(s)
Net Ağırlık 452 g
Bağlantı Tipi cable
Length of cable 10 m
Gross weight 452 g
Housing Material Glass-fibre, reinforced thermoplastic
Scope of delivery Actuator must be ordered separately.
Sensor length 13 mm
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Wire cross-section 0.25 mm² | 23 AWG
Actuation Element Magnet
Direction of motion Head-on to the active surface
IP protection class IP67
Sensor width 88 mm
Switching element 1 NO contact, 1 NC contacts
Switching principle Reed contacts, Non-contact principle
Sensor height 25 mm
Number of cable wires 4
Impact energy, maximum 7 J
Traceparts, product ID 33-22052019-077517
Cross-circuit detection Yes
Short circuit detection Yes
Manufacturer declaration ATEX Zone 2 and 22
Note (Repeat accuracy R) Repeat accuracy R ≤ 0,1 x Sao
Housing construction form Block
Note (switching distance) All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator) EX-BPS 33-3G/D
Explosion protection zones 22 | 2
Mechanical Mounting Conditions not flush
Switching current, maximum 0.4 A
Switching voltage, maximum 100 VAC | 100 VDC
Switching capacity, maximum 10 W
Material of the Cable mantle PVC
Prerequisite evaluation unit Yes
Switching frequency, maximum 5 Hz
Explosion protection category 3G | 3D
Explosion protection designation D II 3G Ex nC IIC T6 Gc X | D II 3D Ex tc IIIC T80°C Dc X
B10D Normally-closed contact (NC) 25,000,000
Explosion protection: regulations EN ISO 80079-37 | EN IEC 60079-0 | EN IEC 60079-15 | EN ISO 80079-36 | EN 60079-31
Assured switching distance "ON" Sao 5 mm
Assured switching distance "OFF" Sar 15 mm
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 1
B10D- Value Normally-closed contact/Normally open contact (NC/NO) 25,000,000

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3