Order No
103047633
Certificates
ATEX
Schmersal
Ex / ATEX Anahtarlama Cihazları
Emniyet Işık Perdeleri ve Izgaraları
EX-SLC440-ER-0810-30
EX-SLC440-ER-0810-30 — Schmersal product. Key specifications: Housing Material: Shatterproof glass; IP protection class: IP66; Ambient Temperature: -25 ... +50 °C; Sensor width: 100 mm; CADENAS: Yes. Article number: 103047633. Request a quote for pricing and lead time; technical data and documents are listed below.
Product Description
- • IP: IP66
- • Sertifika: ATEX
Standards
- • EN ISO 13849-1
- • EN IEC 62061
- • EN IEC 61496-1
- • EN IEC 61496-2
Product Features
- • Ex-Zone 1 and 21
- • Resolution 14 and 30 mm
- • Protected mode
- • Integrated contactor control
- • Beam coding
Technical Specifications
CADENAS
Yes
Category
4
General note
Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
PFH value
5.14 x 10⁻⁹ /h
Traceparts
Yes
Mission time
20 Year(s)
Bağlantı Tipi
Connector
Number of beams
40
Housing Material
Shatterproof glass
7-segment display
Yes
Blanking function
Yes
Scope of delivery
Kit with 2 mounting angles
IP protection class
IP66
Ambient Temperature
-25 ... +50 °C
Performance level
e
Sensor width
100 mm
Beam coding available
Yes
Tolerance, percentage
10 %
Reaction time, maximum
10 ms
Min. Ortam Sıcaklığı
-25 °C
Maks. Ortam Sıcaklığı
+50 °C
Design of control elements
short-circuit proof, p-type
Explosion protection zones
21 | 1
Integral system diagnostics
Yes
Contactor control integrated
Yes
Explosion protection category
2G | 2D
Recommended safety switchgear
SRB-E 301
Terminal connector, Recipient
Connector plug M12, 8-pole
Wave length of the laserdiode
850 nm
Height of the protection field
810 mm
Explosion protection designation
D II 2G Ex db op is IIA T6 Gb | D II 2D Ex op is tb IIIC T80°C Db
Range, protection field, maximum
10 m
Range, protection field, minimum
0.3 m
Restart interlock (manual reset)
Yes
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-28 | EN 60079-31 | EN 60079-1
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Switching voltage OSSD, HIGH signal
24 V
Reaction time with beam coding A, maximum
15 ms
Safety type in accordance with IEC 61496-1
4
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Safety Integrity Level (SIL), suitable for applications in
3