Note
All indications including the conductor ferrules. | at 20% ohmic contact load
Cable Cross-Section
1 mm² ... 2.5 mm²(All indications including the conductor ferrules.)
Mission time
20 Year(s)
Net Ağırlık
320 g
Bağlantı Tipi
Screw terminals M20 x 1.5
Gross weight
320 g
Housing Material
Metal, zinc die-cast
Contact material
Silver
Safety functions
Yes
Min. cable cross-section
1 mm²
Scope of delivery
Ex-certified screwed cable gland
Sensor length
38 mm
Max. cable cross-section
2.5 mm²
Wire cross-section
13 AWG
Actuation Element
Plunger
IP protection class
IP65
Ambient Temperature
-20 °C
Sensor width
40.5 mm
Conventional thermal current
5A
Switching element
2 NC contact
Switching principle
Slow action
Mechanical life (min.)
1,000,000
Note Bounce duration
Bounce duration in accordance with actuating speed
Sensor height
103.5 mm
Utilisation category
AC-15 | AC-1 | DC-13
Maks. Sigorta Değeri
6 A gG D-fuse
Impact energy, maximum
7 J
Note (Switchover time)
Switchover time in accordance with actuating speed
Number of cable glands
1
Max. actuating speed
1 m/s
Actuating force, minimum
17 N
Bounce duration, maximum
3 ms
Housing Coating Material
painted
Min. Ortam Sıcaklığı
-20 °C
Note (Switching element)
Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges
Actuator type to EN 50041
B
Number of safety contacts
1 / 2 | 2
Housing construction form
Norm construction design
Explosion protection zones
21 | 1
Utilization Category AC-15
230 VAC
Utilization Category DC-13
24 VDC
Number of auxiliary contacts
1 / 2
Max. switching frequency
1,800 /h
Explosion protection category
2G | 2D
Rated impulse withstand voltage (Uimp)
4 kV
Manufacturer declaration, zone
21 | 1
B10D Normally-open contact (NO)
1,000,000
Explosion protection designation
D II 2D Ex tb IIIC T80°C Db | D II 2G Ex d e IIC T6 Gb
B10D Normally-closed contact (NC)
20,000,000
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-7 | EN 60079-31 | EN 60079-1
Rated insulation voltage (Uᵢ)
250 VAC
Required rated short-circuit current
1,000 A
Tightening torque of the cable gland
10 Nm
Cable cross-section of the cable glands
7 ... 12 mm
Tightening torque of the earth screw PE
1 Nm
Cable cross-section of the cable glands, maximum
12 mm
Cable cross-section of the cable glands, minimum
7 mm
Ambient temperature, maximum (Cable section 1mm2)
+50 °C
Ambient temperature, maximum (Cable section 2.5mm2)
+55 °C
Tightening torque of the fastening screws for the actuating head
1.5 Nm
Tightening torque of the fastening screws for the switch element
1.2 Nm