EX-TV10S 335-02Z-3D
Order No 151193079
Certificates cULus, ATEX (Konformitätserklärung) cULus
Schmersal Ex / ATEX Anahtarlama Cihazları Hinge Safety Switches

EX-TV10S 335-02Z-3D Hinge Safety Switches

EX-TV10S 335-02Z-3D — Schmersal Hinge Safety Switches. Key specifications: Switching element: 2 NC contact; Housing Material: Aluminium; IP protection class: IP67; Ambient Temperature: -20 ... +60 °C | -20_+60; Sensor length: 60.6 mm. Article number: 151193079. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 116 g
  • • Sertifika: cULus, ATEX (Konformitätserklärung) cULus

Standards

  • • EN ISO 13849-1

Product Features

  • • Ex-Zone 22
  • • Metal enclosure
  • • Actuator shaft can be turned 360°
  • • Actuator heads can be repositioned by 4 x 90°
  • • 40,5 mm x 107 mm x 65,3 mm
  • • Good resistance to oil and petroleum spirit

Technical Specifications

Note All indications including the conductor ferrules.
Cable Cross-Section 0.75 mm² ... 2.5 mm²(All indications including the conductor ferrules.) | 0.75_2.5_PMAW00000660
Mission time 20 Year(s)
Lever material Metal film
Net Ağırlık 116 g
Bağlantı Tipi Screw terminals M20 x 1.5
Gross weight 116 g
Housing Material Aluminium
Contact material Silver
Min. cable cross-section 0.75 mm²
Sensor length 60.6 mm
Max. cable cross-section 2.5 mm²
Cylinder Material Plastic
Wire cross-section 13 AWG
Actuation Element Roller lever
IP protection class IP67
Ambient Temperature -20 ... +60 °C | -20_+60
Sensor width 40.5 mm
Conventional thermal current 10A
Switching element 2 NC contact
Mechanical life (min.) 30,000,000
Sensor height 134 mm
Utilisation category AC-15 | DC-13
Maks. Sigorta Değeri 6 A gG D-fuse
Impact energy, maximum 4 J
Note (Actuating speed) Actuating speed with actuating angle 30° to switch axis
Max. actuating speed 2.5 m/s
Housing Coating Material painted
Manufacturer declaration ATEX Zone 2 and 22
Min. Ortam Sıcaklığı -20 °C
Actuator type to EN 50041 A
Number of safety contacts 2 | 1 / 2
Housing construction form Norm construction design
Maks. Ortam Sıcaklığı +60 °C
Explosion protection zones 22 | 2
Utilization Category AC-15 4 A | 230 VAC
Utilization Category DC-13 4 A | 24 VDC
Number of auxiliary contacts 1
Max. switching frequency 5,000 /h
Mounting hole for the shaft 10 mm
Explosion protection category 3G | 3D
Rated impulse withstand voltage (Uimp) 6 kV
Explosion protection designation D II 3D Ex tc IIIC T90°C Dc X | D II 3G Ex nC IIC T5 Gc X
Explosion protection: regulations EN IEC 60079-0 | EN IEC 60079-15 | EN 60079-31
Rated insulation voltage (Uᵢ) 500 V
Cable cross-section of the cable glands, maximum 12 mm
Cable cross-section of the cable glands, minimum 7 mm