All indications including the conductor ferrules. | at 20% ohmic contact load
Cable Cross-Section
0.75_2.5_PMAW00000660 | 0.75 mm² ... 2.5 mm²(All indications including the conductor ferrules.)
Mission time
20 Year(s)
Lever material
Metal film
Net Ağırlık
270 g
Bağlantı Tipi
Screw terminals M20 x 1.5
Gross weight
270 g
Housing Material
Light alloy die-casting
Contact material
Silver
Safety functions
Yes
Min. cable cross-section
0.75 mm²
Sensor length
57.3 mm
Max. cable cross-section
2.5 mm²
Cylinder Material
Plastic
Wire cross-section
13 AWG
Actuation Element
Roller lever
IP protection class
IP67
Ambient Temperature
-20 ... +60 °C | -20_+60
Sensor width
40.5 mm
Conventional thermal current
10A
Switching element
1 NO contact, 1 NC contacts
Switching principle
Snap action
Mechanical life (min.)
30,000,000
Note Bounce duration
Bounce duration in accordance with actuating speed
Sensor height
173.5 mm
Utilisation category
AC-15 | DC-13
Maks. Sigorta Değeri
6 A gG D-fuse
Impact energy, maximum
1 J
Note (Actuating speed)
Actuating speed with actuating angle 30° to switch axis
Number of cable glands
3
Max. actuating speed
2.5 m/s
Housing Coating Material
painted
Manufacturer declaration
ATEX Zone 2 and 22
Min. Ortam Sıcaklığı
-20 °C
Note (Switching element)
Change-over contact with double break, type Zb or 2 NC contacts, with galvanically separated contact bridges
Switchover time, maximum
2 ms
Actuating torque, minimum
0.3 Nm
Actuator type to EN 50041
A
Number of safety contacts
1
Housing construction form
Norm construction design
Maks. Ortam Sıcaklığı
+60 °C
Explosion protection zones
22 | 2
Utilization Category AC-15
4 A | 230 VAC
Utilization Category DC-13
24 VDC / 1 A | 24 VDC | 1 A
Number of auxiliary contacts
1
Max. switching frequency
5,000 /h
Explosion protection category
3G | 3D
Rated impulse withstand voltage (Uimp)
6 kV
B10D Normally-open contact (NO)
1,000,000
Explosion protection designation
D II 3D Ex tc IIIC T90°C Dc X | D II 3G Ex nC IIC T5 Gc X
B10D Normally-closed contact (NC)
20,000,000
Explosion protection: regulations
EN IEC 60079-0 | EN IEC 60079-15 | EN 60079-31
Rated insulation voltage (Uᵢ)
500 V
Required rated short-circuit current
1,000 A
Cable cross-section of the cable glands
7 ... 12 mm
Tightening torque of the earth screw PA
1.2 Nm
Tightening torque of the earth screw PE
1 Nm
Tightening torque of the cable gland, minimum
8 Nm
Cable cross-section of the cable glands, maximum
12 mm
Cable cross-section of the cable glands, minimum
7 mm
Tightening torque of the fastening screws for the housing cover, minimum
1 Nm