Note
All indications including the conductor ferrules.
General note
For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. | Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. | As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner.
Traceparts
Yes
Cable Cross-Section
0.75_2.5_PMAW00000660 | 0.75 mm² ... 2.5 mm²(All indications including the conductor ferrules.)
Mission time
20 Year(s)
Net Ağırlık
1,600 g
Bağlantı Tipi
Screw terminals M20 x 1.5
Actuating travel
400 mm
Gross weight
1,600 g
Housing Material
Metal, zinc die-cast
Contact material
Silver
Min. cable cross-section
0.75 mm²
Relative humidity
30 ... 95 %
Scope of delivery
Including Ex-certified screwed cable gland and screw plug
Sensor length
57 mm
Max. cable cross-section
2.5 mm²
Actuation direction
One-side operation
IP protection class
IP67
Ambient Temperature
-20 ... +55 °C
Sensor width
71.5 mm
Conventional thermal current
4 A
Switching element
NO contact, NC contact
Switching principle
Snap action
Mechanical life (min.)
1,000,000
Utilisation category
AC-15 | DC-13
Maks. Sigorta Değeri
6 A gG D-fuse
Actuating force, maximum
200 N
Housing Coating Material
painted
Min. Ortam Sıcaklığı
-20 °C
Number of safety contacts
1 | 1 / 2 / 3 / 4
Maks. Ortam Sıcaklığı
+55 °C
Explosion protection zones
22
Utilization Category AC-15
4 A | 230 VAC
Utilization Category DC-13
24 VDC / 1 A | 24 VDC | 1 A
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Number of auxiliary contacts
0 / 1 / 2 | 1
Length of the wire, maximum
75 m
Explosion protection category
3D
Height of the Sensor, maximum
237 mm
Height of the Sensor, minimum
221 mm
Material of the housing cover
Steel
Rated impulse withstand voltage (Uimp)
6 kV
Explosion protection designation
D II 3D Ex tc IIIC T100°C Dc
B10D Normally-closed contact (NC)
100,000
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-31
Rated insulation voltage (Uᵢ)
500 V
Cable cross-section of the cable glands
7 ... 12 mm
Cable cross-section of the cable glands, maximum
12 mm
Cable cross-section of the cable glands, minimum
7 mm