Schmersal MZM 100 B ST2-SD2PREM-A
Order No 101211153
Certificates TÜV cULus
Schmersal System Solutions Series Diagnostic Systems

MZM 100 B ST2-SD2PREM-A Series Diagnostic Systems

Schmersal MZM 100 B ST2-SD2PREM-A features inductive working principle, IP65 IP67 protection class, -25 ... +55 °C ambient temperature and 40 mm sensor length.

Product Description

  • • IP Rating: IP65/IP67
  • • Voltage: 24 VDC
  • • Weight: 620 g
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • Actuator monitored
  • • Connector M12, 8-pole
  • • Power required to lock
  • • serial diagnostic output
  • • Automatic latching
  • • Solenoid interlocks with innovating and unique operating principle
  • • 40 mm x 179 mm x 40 mm
  • • Electronic non-contact coded system
  • • Thermoplastic housing
  • • Max. length of the sensor chain 200 m
  • • 3 LEDs indicating operating status
  • • Sensor technology permits an offset between actuator and interlock of ±5 mm vertically and ±1.5 mm horizontally
  • • Intelligent diagnostics
  • • Kendinden izlemeli seri kablolama

Technical Specifications

PIN 1 A1 Supply voltage UB
PIN 2 X1 Safety input 1
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 OUTPUT serial diagnostic output
PIN 6 X2 Safety input 2
PIN 7 Y2 Safety output 2
PIN 8 INPUT serial diagnostic input
Coding Universal coding
Category 4
General note As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be locked again.
PFH value 3.54 x 10⁻⁹ /h
Shock resistance 30 g / 11 ms
Latching Yes
Mission time 20 Year(s)
Serial Diagnostics Yes
Series Connection Yes
Gross weight 620 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection Class III
Min. Relative Humidity 30 %
Pollution degree 3
Max. Relative Humidity 95 %
Note (Relative Humidity) Non-condensing, non-icing
Sensor length 40 mm
Scope of delivery Actuator must be ordered separately.
Vibration resistance 10 … 150 Hz, amplitude 0.35 mm / 5 g
Cable Capacitance 50 nF
Max. Risk Time 150 ms
Operating current 150 mA
24V Current Consumption 5 mA
IP protection class IP65 IP67
Short-Circuit Detection Yes
Max. reaction time 150 ms
Ambient Temperature -25 ... +55 °C
Performance level e
Sensor width 40 mm
Typical Holding Force 750 N
Operating voltage 24 VDC -15% / +10% (stabilised PELV power supply)
Working Principle inductive
Actuator Monitored Yes
Mechanical life (min.) 1,000,000 Cycles
Note (Mechanical Life) Actuating speed ≤ 0.5 m/s, operating cycles for door weights ≤ 5 kg
Sensor height 177.5 mm
Recommendation (Actuator) MZM 100-B1.1
Switching Thresholds −3 V … 5 V (Low) 15 V … 30 V (High)
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Force to Lock Yes
Min. Locking Force 45 N
Fixing screw type 2x M6
Terminal connection Connector M12, 8-pole
Guaranteed Holding Force 500 N
Max. Leakage Current (Ir) 0.5 mA
Max. Locking Force 115 N
Suitable SIL Applications 3
Safety Functions Yes
Max. installation altitude 2,000 m
Max. Test Pulse Duration 1 ms
Number of safety contacts 2
Max. Ready Time 4,000 ms
Current Utilization Cat. DC-13 0.25 A
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances according to EN IEC 60947-5-3
Overvoltage category III
Magnet Release Time 100 %
Rated operating voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-13 24 VDC
Serial Diagnostics (SD) Definition OUT
Assured Switch-On Distance Sao 0 mm
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 1 V
Magnet Control Definition IN
Number of Sensors Connected in Series 31
Rated impulse withstand voltage (Uimp) 0.8 kV
Assured Switch-Off Distance Sar 1 mm
Control Elements Design Short-circuit proof, p-type
Fixing Screw Tightening Torque 8 Nm
Storage/transport temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Coding level (EN ISO 14119) Low
Max. Sensor Chain Length 200 m
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Safety Outputs Definition Y1 and Y2
Rated insulation voltage (Uᵢ) 32 VDC
Max. Switching Frequency (Approx.) 1 Hz
Required rated short-circuit current 100A
External Wire and Device Fuse Rating 2 A gG
Magnet ON Peak Current Consumption 550 mA / 10 ms
ZVEI CB24I Sink Classification C1
ZVEI CB24I Source Classification C1
Magnet ON Average Current Consumption 350 mA
Typical Idle Operating Current (I₀) 100 mA
Note (LED Switching Condition Indication) Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Rated Operating Current (Safety Outputs) 250 mA