PIN 1
AS-i +
PIN 2
Aux - (P)
PIN 3
AS-Interface -
PIN 4
Aux + (P)
Coding
Universal coding
Category
4
Latching
Yes
General note
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened
PFH value
5.00 x 10⁻⁹ /h
Fuse rating
4 A
AS-i Profile
S-7.B.F.E
AS-i Version
V 2.1
AS-i, ID-Code
0xB
AS-i, IO-Code
0x7
Shock resistance
30 g / 11 ms
Power to lock
Yes
AS-i, ID-Code1
0xF
AS-i, ID-Code2
0xE
Mission time
20 Year(s)
Latching force
30 ... 100 N
Net Ağırlık
705 g
Bağlantı Tipi
Connector plug M12, 4-pole, (A-coding)
Gross weight
705 g
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
III
Safety functions
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply)
Relative humidity
30 ... 95 %
Scope of delivery
Actuator must be ordered separately.
Sensor length
40 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm
AS-i Outputs, DO 0
Solenoid control
AS-i Outputs, DO 1
For the variable setting of the latching force
AS-i Outputs, DO 2
For the variable setting of the latching force
AS-i Outputs, DO 3
For the variable setting of the latching force
AS-i Specification
Safety-Slave
Current consumption
600 mA
IP protection class
IP67
Note voltage AUX DC
stabilised PELV power supply
Ambient Temperature
-25 ... +55 °C
Performance level
e
Sensor width
40 mm
Working Principle
inductive
Mechanical life (min.)
1,000,000
Sensor height
179 mm
AS-i Input, Channel 1
Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2
Data bits DI 2 / DI 3 = dynamic code transmission
Magnet switch-on time
100 %
AS-i Device protection
Internal short-circuit proof
Reaction time, maximum
150 ms
Traceparts, product ID
69-05102007-016632
AS-i Parameter bits, P0
Actuator in
AS-i Parameter bits, P1
Solenoid interlock locked
AS-i Parameter bits, P2
Auxiliary voltage in
AS-i Parameter bits, P3
Device error (fault detected)
Latching force, maximum
100 N
Latching force, minimum
30 N
Holding force, typically
750 N
Min. Ortam Sıcaklığı
-25 °C
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
AS-i Input module address
0
Duration of risk, maximum
150 ms
Holding force, guaranteed
500 N
Maks. Ortam Sıcaklığı
+55 °C
Recommendation (actuator)
MZM 100-B1.1
Note (Mechanical lifetime)
Actuating speed ≤ 0.5 m/s | Operations for door weights ≤ 5 kg
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Time to readiness, maximum
4,000 ms
Overvoltage category
3 | III
Nominal Çalışma Voltajı
24 VDC -15% / +10% (stabilised PELV) | 26.5 ... 31.6 VDC (Protection against polarity reversal) | 24 VDC
Note (AS-i Parameter bits)
Set the parameter outputs to "1111" (0xF)
Solenoid interlock monitored
Yes
Note (AS-i Operating voltage)
Protection against polarity reversal
Rated impulse withstand voltage (Uimp)
0.8 kV
AS-i Operating voltage, minimum
26.5 VDC
Note (AS-i Input module address)
Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
AS-i Current consumption, maximum
100 mA
Depolama / Taşıma Sıcaklığı
-25 ... +85 °C | -40 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
AS-i Operating voltage AS-i maximum
31.6 VDC
Integral system diagnostics, status
Yes
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
Low
Note (LED switching conditions display)
(2) LED yellow: Device condition | (1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 | (3) LED red: Internal device error
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-25 °C
Safety Integrity Level (SIL), suitable for applications in
3