PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Coding
Universal coding
Category
4
Latching
Yes
General note
As long as the actuating unit is applied to the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
PFH value
3.54 x 10⁻⁹ /h
Voltage type
DC
Shock resistance
30 g / 11 ms
Power to lock
Yes
Series-wiring
Yes
Mission time
20 Year(s)
Latching force
15 / 30 / 45 / 60 / 100 N | 30 N
Net Ağırlık
618 g
Bağlantı Tipi
Connector M12, 8-pole
Gross weight
618 g
Housing Material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Protection class
III
Safety functions
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Relative humidity
30 ... 95 %
Scope of delivery
Actuator must be ordered separately.
Sensor length
40 mm
Vibration resistance
10 … 150 Hz, amplitude 0.35 mm / 5 g
Operating current
1,100 mA | 50 mA
IP protection class
IP67 | IP65
Ambient Temperature
-25 ... +55 °C
Performance level
e
Sensor width
40 mm
Working Principle
inductive
Mechanical life (min.)
1,000,000
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
177.5 mm
Switching thresholds
-3 V … 5 V (Low) | −3 V … 5 V (Low) | 15 V … 30 V (High)
Magnet switch-on time
100 %
Electrical fuse rating
short-circuit proof, p-type
Reaction time, maximum
150 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Holding force, typically
750 N
Min. Ortam Sıcaklığı
-25 °C
Minimum distance devices
100 mm
Note (Delivery capacity)
Not available!
Note (Relative humidity)
non-condensing | non-icing
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
150 ms
Holding force, guaranteed
500 N
Maks. Ortam Sıcaklığı
+55 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
MZM 100-B1.1
Type of the fixing screws
2x M6
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05
Note (Mechanical lifetime)
Actuating speed ≤ 0.5 m/s | Operations for door weights ≤ 5 kg
Operating voltage, maximum
26.4 VDC
Operating voltage, minimum
20.4 VDC
Relative humidity, maximum
95 %
Relative humidity, minimum
30 %
Time to readiness, maximum
4,000 ms
Overvoltage category
3 | III
Current consumption at 24 V
5 mA | 10 mA
Designation, Magnet control
IN
Designation, Safety outputs
Y1 and Y2
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Solenoid interlock monitored
Yes
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
5 ms | 1 ms
Test pulse interval, minimum
40 ms | 100 ms
Test pulse interval, typical
1,000 ms
Rated impulse withstand voltage (Uimp)
0.8 kV
Fuse rating to UL 508, maximum
2 A
Classification ZVEI CB24I, Sink
C1 | C0
Designation, Diagnostic outputs
OUT
Length of sensor chain, maximum
200 m
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Classification ZVEI CB24I, Source
C3 | C1 | C2
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
100 mA
Number of digital fail-safe inputs
2
Assured switching distance "ON" Sao
0 mm
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-13
24 VDC
Assured switching distance "OFF" Sar
1 mm
External wire and device fuse rating
2 A gG (Connector M12, 8-pole) | 2 A gG
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
Low
Tightening torque of the fixing screws
8 Nm
Note (LED switching conditions display)
Error / functional defect: LED red | Operating condition: LED green | Supply voltage UB: LED green
Current consumption with magnet ON, peak
550 mA / 10 ms
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Current consumption with magnet ON, average
350 mA
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
3
Angular misalignment between solenoid interlock and actuator, maximum
2 °