Order No
103012161
Certificates
cULus
Schmersal
System Solutions
Series Diagnostic Systems
PDM-SD-4CC-SD Series Diagnostic Systems
Schmersal PDM-SD-4CC-SD features cam elyaf takviyeli termoplastik housing material, IP00 protection class, -25 ... +65 °C ambient temperature and 67.7 mm depth.
Product Description
- • IP Rating: IP00
- • Voltage: 24 VDC
- • Dimensions: 45mm×105.4mm×67.7mm
- • Weight: 120 g
- • Certification: cULus
Standards
- • EN IEC 60947-1
Product Features
- • For SD-Interface devices
- • Passive distribution module for series-wiring
- • Cage clamps
- • For up to 4 safety switchgears
- • Fuse protected device ports
- • For installation in terminal boxes
- • Protection class IP00
Technical Specifications
Note
All specifications include conductor ferrules.
Mounting
Snaps onto standard DIN rail according to IEC 60715
Depth
67.7 mm
Width
45 mm
LED Colour
Green
LED Status
Power-LED module
LED Position
POWER
Height
105.4 mm
Number of LEDs
5
Shock resistance
30 g / 11 ms
Gross weight
120 g
Housing Material
Glass-fibre reinforced thermoplastic
Protection Class
III
Min. Relative Humidity
5 %
Pollution degree
2
Max. Relative Humidity
95 %
Min. cable cross-section
0.25 mm²
Note (Relative Humidity)
Non-condensing
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Max. cable cross-section
1.5 mm²
Terminal (Mechanical)
cage terminals
Operating current
10,000 mA
IP protection class
IP00
Ambient Temperature
-25 ... +65 °C
Operating voltage
24 VDC -15% / +10% (stabilised PELV power supply)
Max. installation altitude
2,000 m
Internal Electrical Fuse
1,5 A (integrated self-resetting fuse)
Rated operating current
800 mA
Overvoltage category
III
Rated operating voltage
24 VDC
Rated impulse withstand voltage (Uimp)
0.8 kV
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Rated insulation voltage (Uᵢ)
32 VDC
Note (Electrical Data Fuse Rating)
When used for UL 61010, external fuse protection ≤ 10A slow-blow is required.