PS216-T20-ST-K250-U4
Order No 103049227
Certificates cULus CCC cULus,
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

PS216-T20-ST-K250-U4

PS216-T20-ST-K250-U4 — Schmersal product. Key specifications: Switching principle: Slow action; Switching element: 2 NO contact; Housing Material: Plastic, glass-fibre-reinforced; IP protection class: IP66 | IP67; Ambient Temperature: -30 ... +80 °C. Article number: 103049227. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 80 g
  • • Sertifika: cULus CCC cULus,

Standards

  • • EN ISO 13849-1
  • • EN IEC 60947-5-1

Product Features

  • • thermoplastic enclosure with foldable latching cover
  • • Simple and quick to adjust the control elements by 45°.
  • • Design to EN 50047
  • • Actuation from bottom parallel to the switch, therefore only suitable for small housings.
  • • LED version available

Technical Specifications

Traceparts Yes
Cable Cross-Section 0.34 mm² ... 1.5 mm²
Net Ağırlık 80 g
Bağlantı Tipi Connector plug M12, 4-pole
Gross weight 80 g
Housing Material Plastic, glass-fibre-reinforced
Contact material Silver
Protection class II
Actuator rotation 180 °
Pollution degree 3
Min. cable cross-section 0.34 mm²
Sensor length 32.5 mm
Connector position Bottom
Diameter of Castor 22 mm
Max. cable cross-section 1.5 mm²
Actuation Element Angle roller lever K250
IP protection class IP66 | IP67
Ambient Temperature -30 ... +80 °C
Sensor width 31 mm
Conventional thermal current 4 A
Switching element 2 NO contact
Switching principle Slow action
Mechanical life (min.) 10,000,000
Sensor height 107 mm
Maks. Sigorta Değeri 6 A gG D-fuse
Min. Actuation Speed 60 mm/min
Max. actuating speed 1 m/s
Min. Ortam Sıcaklığı -30 °C
Actuator type to EN 50047 E
Number of safety contacts 1 / 2
Housing construction form Norm construction design
Maks. Ortam Sıcaklığı +80 °C
Utilization Category AC-15 50 VAC | 3 A
Utilization Category DC-13 24 VDC / 3 A | 3 A | 24 VDC
Number of auxiliary contacts 1 / 2 | 2
Max. switching frequency 5,000 /h
Positive break force, minimum 40 N
Rated impulse withstand voltage (Uimp) 0.8 kV
Rated insulation voltage (Uᵢ) 240 V
Required rated short-circuit current 400A
Tightening torque of the fixing screws 1.2 Nm
Tightening torque of electrical connection, maximum 0.8 Nm
Tightening torque of electrical connection, minimum 0.6 Nm