RSS 36-D-ST
Order No 101213954
Article Code 101213954
Certificates TÜV cULus ECOLAB FCC IC ANATEL
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

RSS 36-D-ST

Product Description

  • • IP Rating: IP65/IP67/IP69 | Voltage: 24 VDC | Weight: 80 g | PL e

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • Universal coding with RFID technology_x000D_
  • • 1 x connector socket M12, 8-pole_x000D_
  • • Yandan aktüasyon_x000D_
  • • Termoplastik gövde_x000D_
  • • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
  • • Misaligned actuation possible_x000D_
  • • 27 mm x 108.2 mm x 35 mm_x000D_
  • • High repeat accuracy of the switching points_x000D_
  • • 2 short-circuit proof PNP safety outputs_x000D_
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Technical Specifications

PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND Blue
PIN 4 Y1 Safety output 1 Black
PIN 5 OUTPUT Diagnostics output OUT Grey
PIN 6 X2 Safety input 2 violet
PIN 7 Y2 Safety output 2 red
PIN 8 Fonksiyonsuz INPUT Pembe
Mounting 25 mm screw length sensor mounting and of the actuators side mounting for is sufficient. Actuator vertical mounted when done and/or sealing of the discs used cases 30 mm in length screws is recommended.
Coding Universal coding
Category 4
General Note Evaluation requirements: two-channel safety input, suitable for p-switching sensors with NO function.
Active Area Yanal
PFD Value 2.10 x 10⁻⁵
PFH Value 2.70 x 10⁻¹⁰ /h
Number of LEDs 3
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Max. Hysteresis 2 mm
Series Connection Yes
Gross Weight 80 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class III
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor Length 22 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Risk Time 200 ms
Sensor Topology Series connection for sensor
Operating Current 600 mA
IP Protection Class IP65 IP67 IP69
Short-Circuit Detection Yes
Max. Response Time 100 ms
Ambient Temperature -28 ... +70 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 106.3 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Actuation Panels Yanal
Cascadable Yes
Mechanical Life (min.) 1,000,000 Cycles
Housing Design Form Blok
Note (Mechanical Life) Actuating speed < 0.25 m/s Cycles for door weights ≤ 5 kg
Sensor Height 25 mm
Recommendation (Actuator) RST 36-1 RST 36-1-R
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output Yes
Cross-Circuit Detection Yes
Fixing Screw Type 2x M4 (DIN 125A / form A washers with cylindrical headed screws)
Terminal Connection Connector M12, 8-pole
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Test Pulse Duration 0.3 ms
Max. Ready Time 2,000 ms
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Mechanical Mounting Conditions Embedded not
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment (x) of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems.
Typical Switching Distance 12 mm
Overvoltage Category III
Rated Operating Voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Min. Fixing Screw Torque 2.2 Nm
Guaranteed Opening Distance (ON) Sao 10 mm
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 2 V
Max. Fixing Screw Torque 2.5 Nm
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 20 mm
Control Elements Design Short devre resistant, p-type
Storage/Transport Temperature -28 ... +85 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) Low
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 0.08333333333212067
Rated Insulation Voltage (Uᵢ) 32 VDC
Diagnostic Outputs Definition OUT
Max. Switching Frequency (Approx.) 1 Hz
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
ZVEI CB24I Sink Classification C1 C2
Safety Inputs Current Consumption 5 mA
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 35 mA
Max. Output Current (Safe Output) 0.25 A
Note (LED Switching Condition Indication) Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms
Max. Response Time (Safety Input to Safety Output Off) 0.5 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.