EPLAN
Yes
PIN 1
1A1 Ue: (1)
PIN 2
X1 Safety input 1
PIN 3
A2 GND Blue
PIN 4
Y1 Safety output 1 Black
PIN 5
OUT Diagnostic output OUT Grey
PIN 6
X2 Safety input 2 violet
PIN 7
Y2 Safety output 2 red
PIN 8
IN without function Pink
Coding
Individual coding
Mounting
A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.
Category
4
General note
During the individual coding, a RST actuator is taught through a simple routine during start-up, so that any tampering by means of a spare or substitute actuator is permanently excluded. | Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 1 ms müssen von der Auswertung toleriert wer
PFD value
2.10 x 10⁻⁵
PFH value
2.70 x 10⁻¹⁰ /h
Cable type
LiYY
Cascadable
Yes
Active area
lateral
Cable Cross-Section
8 mm²
Lead colours
Black
Voltage type
DC
Shock resistance
30 g / 11 ms
Series-wiring
Yes
Mission time
20 Year(s)
Latching force
18 N
Net Ağırlık
80 g
Number of LEDs
3
Bağlantı Tipi
Cable (Y-UL 2517), 8-pole
Connection type
Cable (Y-UL 2517), 8-pole, Connector M12, 8-pole, Connector M12, 5-pole, A-coded
Length of cable
2 m
Sensor topology
Sensor for series wiring
Actuating panels
lateral
Gross weight
80 g
Current derating
Ambient temperature -25°C … +65°C: ≤ 0.25 A | Ambient temperature -25°C … +70°C: ≤ 0.1 A
Housing Material
Glass-fibre, reinforced thermoplastic
Protection class
III
Safety functions
Yes
Diagnostic output
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (stabilised PELV power supply) | 24 VDC -15 % / +10 % (PELV to EN 60204-1)
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
22 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Max. cable cross-section
8 x 0.35 mm²
Wire cross-section
22 AWG
Wiring capacitance
50 nF
Operating current
600 mA | 150 mA
Frequency band RFID
125 kHz
IP protection class
IP69 | IP67 | IP65
Ambient Temperature
-28 ... +70 °C
Performance level
e
Sensor width
106.3 mm
Working Principle
RFID
Degree of protection
IP65, IP67, IP69
Mechanical life (min.)
1,000,000
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
25 mm
Interfering radiation
IEC 61000-6-4
Electrical fuse rating
short-circuit proof
Reaction time, maximum
100 ms
Cross-circuit detection
Yes
Short circuit detection
Yes
Min. Ortam Sıcaklığı
-28 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance
Switch distance, typical
12 mm
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
200 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+70 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator)
RST 36-1 | RST 36-1-R
Type of the fixing screws
2x M4 (cylinder head screws with washers DIN 125A / form A)
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05
Mechanical Mounting Conditions
not flush
Note (Mechanical lifetime)
Actuating speed < 0.25 m/s | Operations for door weights ≤ 5 kg
Operating current, minimum
0.5 mA
Operating voltage, maximum
26.4 VDC
Operating voltage, minimum
20.4 VDC
Relative humidity, maximum
93 %
Time to readiness, maximum
2,000 ms
Utilisation category DC-12
24 VDC / 0.25 A | 24 VDC / 0.05 A | 24_0.05 | 24_0.25
Overvoltage category
3 | III
Designation, Safety outputs
Y1 and Y2
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC −15 % / +10 % | 24 VDC
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
0.3 ms | 1 ms
Test pulse interval, minimum
100 ms
Test pulse interval, typical
1,000 ms
Recommended safety switchgear
SRB-E-301ST | SRB-E-201LC | PROTECT PSC1
Rated impulse withstand voltage (Uimp)
0.8 kV
Classification ZVEI CB24I, Sink
C1 | C2
Designation, Diagnostic outputs
OUT
Electrical fuse rating, maximum
2 A
Rated operating voltage, maximum
26.4 VDC
Rated operating voltage, minimum
20.4 VDC
Transmitter output RFID, maximum
-6 dBm
Absicherung des Diagnoseausganges
short-circuit proof
Classification ZVEI CB24I, Source
C1 | C2 | C3
Depolama / Taşıma Sıcaklığı
-28 ... +85 °C
Rated insulation voltage (Uᵢ)
32 VDC
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
35 mA
Assured switching distance "ON" Sao
10 mm
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Absicherung des Sicherheitsausganges
short-circuit proof
Assured switching distance "OFF" Sar
16 mm
Protection class (Operating resource)
3
Coding level according to EN ISO 14119
High | I1 variant: HighI2 variant: HighStandard coded variant: Low
Tightening torque of the fixing screws
2.2 ... 2.5 Nm
Note (LED switching conditions display)
LED green: Supply voltage | LED red: Fault | LED yellow: Operating condition
Current consumption of the safety inputs
5 mA
Hysteresis (Switching distance), maximum
2 mm
Rated operating current (safety outputs)
250 mA
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-28 °C
Output current, (fail-safe output), maximum
0.25 A
Tightening torque of the fixing screws, maximum
2.5 Nm
Tightening torque of the fixing screws, minimum
2.2 Nm
Number of semi-conductor outputs with signaling function
1
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
3
Material temperature resistance of the cable (at rest), minimum
-30 °C
Material temperature resistance of the cable (in motion), minimum
-10 °C
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
0.5 ms