Schmersal RSS 36-SD-ST
Order No 101214772
Certificates TÜV cULus ECOLAB FCC IC ANATEL
Schmersal System Solutions Series Diagnostic Systems

RSS 36-SD-ST Series Diagnostic Systems

Schmersal RSS 36-SD-ST features RFID working principle, cam elyaf takviyeli termoplastik housing material, IP65 IP67 IP69 protection class and -28 ... +70 °C ambient temperature.

Series: Sensors →

Product Description

  • • IP Rating: IP65/IP67/IP69
  • • Voltage: 24 VDC
  • • Weight: 85 g
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • Universal coding with RFID technology
  • • 1 x connector socket M12, 8-pole
  • • Actuation from the side
  • • Max. 31 sensors can be wired in series.
  • • serial diagnostic output
  • • Thermoplastic housing
  • • RFID technology for demand-based tamper protection
  • • Misaligned actuation possible
  • • 27 mm x 108.2 mm x 35 mm
  • • High repeat accuracy of the switching points
  • • 2 short-circuit proof PNP safety outputs
  • • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Technical Specifications

PIN 1 1A1 Ue: (1)
PIN 2 X1 Safety input 1
PIN 3 A2 GND Blue
PIN 4 Y1 Safety output 1 Black
PIN 5 OUT serial diagnostic output: grey
PIN 6 X2 Safety input 2 violet
PIN 7 Y2 Safety output 2 red
PIN 8 INPUT serial diagnostic input Pink
Mounting A screw length of 25 mm is sufficient for mounting the sensor and for lateral mounting of the actuators. If the actuator is mounted vertically and/or sealing discs are used, 30 mm long screws are recommended.
Coding Universal coding
Category 4
General note Evaluation requirements: two-channel safety input, suitable for p-switching sensors with NO function.
Active Area Lateral
PFD Value 2.10 x 10⁻⁵
PFH value 2.70 x 10⁻¹⁰ /h
Number of LEDs 3
Shock resistance 30 g / 11 ms
Mission time 20 Year(s)
Max. Hysteresis 2 mm
Serial Diagnostics Yes
Series Connection Yes
Gross weight 85 g
Housing Material Glass-fibre reinforced thermoplastic
Protection Class III
Pollution degree 3
Max. Relative Humidity 93 %
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor length 22 mm
Scope of delivery Actuator must be ordered separately.
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Cable Capacitance 50 nF
Max. Risk Time 200 ms
Sensor Topology Sensor for series connection
Operating current 150 mA
IP protection class IP65 IP67 IP69
Short-Circuit Detection Yes
Max. reaction time 100 ms
Ambient Temperature -28 ... +70 °C
Performance level e
RFID Frequency Band 125 kHz
Sensor width 106.3 mm
Operating voltage 24 VDC -15% / +10% (stabilised PELV power supply)
Working Principle RFID
Actuation Panels Lateral
Cascadable Yes
Mechanical life (min.) 1,000,000 Cycles
Housing Design Block
Note (Mechanical Life) Actuating speed < 0.25 m/s, operating cycles for door weights ≤ 5 kg
Sensor height 25 mm
Recommendation (Actuator) RST 36-1 RST 36-1-R
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Fixing screw type 2x M4 (cheese-head screws with DIN 125A / form A washers)
Terminal connection Connector M12, 8-pole
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. installation altitude 2,000 m
Max. Test Pulse Duration 0.3 ms
Max. Ready Time 2,000 ms
Current Utilization Cat. DC-12 0.25 A
Current Utilization Cat. DC-13 0.25 A
Mechanical Mounting Conditions Non-flush
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances according to EN IEC 60947-5-3
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment (x) of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems.
Typical Switching Distance 12 mm
Overvoltage category III
Rated operating voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Min. Fixing Screw Torque 2.2 Nm
Serial Diagnostics (SD) Definition OUT
Assured Switch-On Distance Sao 10 mm
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 1 V
Max. Fixing Screw Torque 2.5 Nm
Max. Transmitter RFID Output -6 dBm
Number of Sensors Connected in Series 31
Rated impulse withstand voltage (Uimp) 0.8 kV
Assured Switch-Off Distance Sar 20 mm
Control Elements Design Short-circuit proof, p-type
Storage/transport temperature -28 ... +85 °C
Integrated System Diagnostics Status Yes
Coding level (EN ISO 14119) Low
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 2 A
Rated insulation voltage (Uᵢ) 32 VDC
Max. Switching Frequency (Approx.) 1 Hz
Required rated short-circuit current 100A
Number of Safe Digital Outputs 2
ZVEI CB24I Sink Classification C1 C2
Safety Inputs Current Consumption 5 mA
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 35 mA
Max. Output Current (Safe Output) 0.25 A
Note (LED Switching Condition Indication) Yellow LED: operating status Green LED: supply voltage Red LED: fault
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms
Max. Response Time (Safety Input to Safety Output Off) 0.5 ms