RSS16-I2-SD-R-ST8H
Order No 103009529
Certificates TÜV, cULus, FCC, IC, ANATEL cULus TÜV IC FCC
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

RSS16-I2-SD-R-ST8H

RSS16-I2-SD-R-ST8H — Schmersal product. Key specifications: Working Principle: RFID; IP protection class: IP66 | IP67 | IP65; Ambient Temperature: -28 ... +70 °C; Sensor length: 91 mm; Sensor width: 52 mm. Article number: 103009529. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 195 g
  • • Sertifika: TÜV, cULus, FCC, IC, ANATEL cULus TÜV IC FCC

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN ISO 13849-1

Product Features

  • • Repeated individual coding with RFID technology
  • • Coding level "High" according to ISO 14119
  • • 1 x connector plug M12, 8-pole
  • • Series-wiring up to 31 components
  • • with latching
  • • Door stop with magnetic latching
  • • Thermoplastic enclosure
  • • RFID-technology for needs-based protection against tampering
  • • 3 different directions of actuation
  • • Connection terminal or plug connection
  • • Suitable for series-wiring

Technical Specifications

EPLAN Yes
Coding Individual coding, multiple teaching
Mounting 2 x M5, Cylinder head screw
CADENAS Yes
Category 4
PFD value 1.50 x 10⁻⁵
PFH value 6.30 x 10⁻¹¹ /h
Cascadable Yes
Traceparts Yes
Active area front side | Glass-fibre, reinforced thermoplastic | cover-side | lateral
Cable Cross-Section 0.25 mm² ... 1.5 mm² | 0.25 mm² ... 1.5 mm² (All indications including the conductor ferrules.)
Voltage type DC
Shock resistance 30 g / 11 ms
Cable entry M12 (A-coding)
Series-wiring Yes
Mission time 20 Year(s)
Net Ağırlık 195 g
Number of LEDs 2
Bağlantı Tipi Connector M12, 8-pole
Latching magnet Yes
Sensor topology Sensor for series wiring
Actuating panels from head | front side | rear
Gross weight 195 g
Housing Material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Safety functions Yes
Pollution degree 3
Min. cable cross-section 0.25 mm²
Operating voltage 24 VDC -15 % / +10 %
Operation current 150 mA
Repeat accuracy R 0.5 mm
Scope of delivery Actuator must be ordered separately.
Sensor length 91 mm
Max. cable cross-section 1.5 mm²
Serial diagnostics Yes
Wiring capacitance 50 nF
Operating current 2,100 mA | 50 mA
IP protection class IP66 | IP67 | IP65
Ambient Temperature -28 ... +70 °C
Performance level e
Sensor width 52 mm
Working Principle RFID
Note (series-wiring) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height 30 mm
Switching thresholds −3 V … 5 V (Low) | 15 V … 30 V (High)
Interfering radiation IEC 61000-6-4
Reaction time, maximum 100 ms
Cross-circuit detection Yes
Short circuit detection Yes
Min. Ortam Sıcaklığı -30 °C | -28 °C
Note (Relative humidity) non-condensing | non-icing
Switch distance, typical 15 mm
Voltage drop Ud, maximum 2 V | 1 V
Duration of risk, maximum 200 ms
Housing construction form Block
Maks. Ortam Sıcaklığı +70 °C
Note (switching distance) All switching distances in accordance EN IEC 60947-5-3
Recommendation (actuator) RST16-1-R
Design of control elements short-circuit proof, p-type | p-type
Designation, Safety inputs X1 and X2
Utilization Category DC-13 24 VDC / 1 A | 24_0.05
Mechanical Mounting Conditions not flush
Operating current, minimum 0.5 mA
Relative humidity, maximum 93 %
Time to readiness, maximum 2,000 ms
Utilisation category DC-12 24_1 | 24 VDC / 0.05 A | 24 VDC / 1 A | 24_0.05
Overvoltage category 3 | III
Leakage current Ir, maximum 0.5 mA
Nominal Çalışma Voltajı 24 VDC
Switching frequency, maximum 1 Hz
Test pulse duration, maximum 1 ms
Test pulse interval, minimum 100 ms
Recommended safety switchgear PROTECT PSC1
Rated impulse withstand voltage (Uimp) 0.8 kV
Classification ZVEI CB24I, Sink C1
Rated operating voltage, maximum 26.4 VDC
Rated operating voltage, minimum 20.4 VDC
Absicherung des Diagnoseausganges short-circuit proof, p-type
Classification ZVEI CB24I, Source C1 | C2 | C3
Depolama / Taşıma Sıcaklığı -28 ... +85 °C
Designation, Serial diagnostic SD OUT
Rated insulation voltage (Uᵢ) 32 VDC
Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical 100 mA
Number of digital fail-safe inputs 2
Number of series-wiring of sensors 31
Assured switching distance "ON" Sao 5 mm
Current, Utilisation category DC-12 0.05 A | 1 A
Current, Utilisation category DC-13 1 A | 0.05 A
Required rated short-circuit current 100A
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Voltage, Utilisation category DC-12 24 VDC
Voltage, Utilisation category DC-13 24 VDC
Absicherung des Sicherheitsausganges short-circuit proof, p-type
Assured switching distance "OFF" Sar 30 mm
Coding level according to EN ISO 14119 High
Tightening torque of the fixing screws 2 Nm
Note (LED switching conditions display) LED green: Supply voltage | Multi-coloured LED: Green, Red | LED red: Fault | LED yellow: Operating condition
Current consumption of the safety inputs 5 mA
Hysteresis (Switching distance), maximum 2 mm
Rated operating current (safety outputs) 1,000 mA
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -28 °C
Output current, (fail-safe output), maximum 1 A
Number of semi-conductor outputs with signaling function 1
Permissible installation altitude above sea level, maximum 2,000 m
Safety Integrity Level (SIL), suitable for applications in 3