RSS260-D-ST
Order No 103003602
Article Code 103003602
Certificates TÜV cULus FCC IC ANATEL
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

RSS260-D-ST

Product Description

  • • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 48 g | PL e

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • Universal coding with RFID technology_x000D_
  • • 1 x connector plug M8_x000D_
  • • Frontal and lateral actuation enabled_x000D_
  • • Termoplastik gövde_x000D_
  • • Simple mounting without additional angle_x000D_
  • • İhtiyaca dayalı müdahale koruması için RFID teknolojisi

Technical Specifications

PIN 1 A1 U e : White
PIN 2 X1 safety input 1: Kahverengi
PIN 3 A2 GND: Green
PIN 4 Y1 safety output 1: Yellow
PIN 5 OUTPUT Diagnostics output OUT Grey
PIN 6 X2 safety input 2: Pembe
PIN 7 Y2 safety output 2: Mavi
PIN 8 Fonksiyonsuz INPUT: Red
Mounting 20 mm screw length genellikle sensor mounted etmek for is sufficient. Mounting plates when used 25 mm in length screws we recommend.
Coding Universal coding
Category 4
Note (Sao) The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area lateral front
PFD Value 1.20 x 10⁻⁴
PFH Value 6.80 x 10⁻¹⁰ /h
Number of LEDs 3
Number of Poles 8
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Max. Hysteresis 2 mm
Series Connection Yes
Gross Weight 48 g
Housing Material Plastik, termoplastik, automatically fading
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor Length 29.5 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Risk Time 200 ms
Sensor Topology Series connection for sensor
Operating Current 50 mA
IP Protection Class IP65 IP67
Short-Circuit Detection Yes
Max. Response Time 100 ms
Ambient Temperature -28 ... +65 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 39.2 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Actuation Panels lateral front taraf
Cascadable Yes
Housing Design Form Blok
Sensor Height 18 mm
Recommendation (Actuator) RST16-1 RST-U-2 RST260-1
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output Yes
Cross-Circuit Detection Yes
Fixing Screw Type 2x M4
Terminal Connection Connector M8, 8-pole
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Test Pulse Duration 1 ms
Max. Ready Time 2,000 ms
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Mechanical Mounting Conditions Embedded not
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage Category III
Rated Operating Voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 2 V
Max. Fixing Screw Torque 0.8 Nm
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Control Elements Design Short devre resistant, p-type
Storage/Transport Temperature -28 ... +85 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) Low
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 0.08333333333212067
Rated Insulation Voltage (Uᵢ) 32 VDC
Diagnostic Outputs Definition OUT
Max. Switching Frequency (Approx.) 1 Hz
Typical Lateral Switching Distance 9 mm
Typical Frontal Switching Distance 12 mm
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
ZVEI CB24I Sink Classification C1 C2
Safety Inputs Current Consumption 5 mA
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 35 mA
Max. Output Current (Safe Output) 0.25 A
Note (LED Switching Condition Indication) Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Guaranteed Open Lateral Switching Distance 6 mm
Guaranteed Open Frontal Switching Distance 10 mm
Guaranteed Closed Lateral Switching Distance 15 mm
Guaranteed Closed Frontal Switching Distance 18 mm
Number of Semiconductor Outputs with Signal Function 1
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3