PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
without function
Coding
Individual coding
Mounting
A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws.
Category
4
PFD value
1.20 x 10⁻⁴
PFH value
6.80 x 10⁻¹⁰ /h
Cascadable
Yes
Note (Sao)
The specifications of the safety switching distance Sao refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active area
front | lateral | Glass-fibre, thermoplastic
Voltage type
DC
Shock resistance
30 g / 11 ms
Series-wiring
Yes
Mission time
20 Year(s)
Net Ağırlık
44 g
Number of LEDs
3
Connection type
cable; Connector M12, 5-pole, A-coded; Connector M12, 8-pole, A-coded; Connector M8, 8-pole
Number of poles
8
Sensor topology
Sensor for series wiring
Actuating panels
lateral | front side
Gross weight
44 g
Feedback circuit
Yes
Housing Material
Glass-fibre, thermoplastic
Safety functions
Yes
Diagnostic output
Yes
Pollution degree
3
Operating voltage
24 VDC -15 % / +10 % (PELV to EN 60204-1)
Repeat accuracy R
0.5 mm
Scope of delivery
Actuator must be ordered separately.
Sensor length
29.5 mm
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Wiring capacitance
50 nF
Operating current
600 mA | 50 mA | 150 mA
Frequency band RFID
125 kHz
IP protection class
IP67 | IP65
Ambient Temperature
-28 ... +65 °C
Performance level
e
Sensor width
39.2 mm
Working Principle
RFID
Degree of protection
IP65, IP67
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Sensor height
18 mm
Interfering radiation
IEC 61000-6-4
Terminal connection
Connector plug M12, 8-pole, A-coded
Cross-circuit detection
Yes
Short circuit detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-28 °C
Note (Relative humidity)
non-condensing | non-icing
Note (Repeat accuracy R)
Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance
Voltage drop Ud, maximum
2 V | 1 V
Duration of risk, maximum
200 ms
Housing construction form
Block
Maks. Ortam Sıcaklığı
+65 °C
Note (switching distance)
All switching distances in accordance EN IEC 60947-5-3 | Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the t
Recommendation (actuator)
RST-U-2 | RST16-1 | RST260-1
Type of the fixing screws
2x M4
Design of control elements
short-circuit proof, p-type
Designation, Safety inputs
X1 and X2
Utilization Category DC-13
24 VDC / 0.25 A | 24_0.05 | 24 VDC / 0.05 A
Mechanical Mounting Conditions
not flush
Operating current, minimum
0.5 mA
Relative humidity, maximum
93 %
Time to readiness, maximum
2,000 ms
Utilisation category DC-12
24 VDC / 0.25 A | 24_0.05 | 24 VDC / 0.05 A
Overvoltage category
3 | III
Current consumption at 24 V
5 mA
Designation, Safety outputs
Y1 and Y2
Leakage current Ir, maximum
0.5 mA
Nominal Çalışma Voltajı
24 VDC
Contactor control integrated
Yes
Switching frequency, maximum
1 Hz
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Test pulse interval, typical
1,000 ms
Rated impulse withstand voltage (Uimp)
0.8 kV
Classification ZVEI CB24I, Sink
C1
Designation, Diagnostic outputs
OUT
Electrical fuse rating, maximum
2 A
Transmitter output RFID, maximum
-6 dBm
Absicherung des Diagnoseausganges
short-circuit proof, p-type
Classification ZVEI CB24I, Source
C1 | C2 | C3
Depolama / Taşıma Sıcaklığı
-28 ... +85 °C
Rated insulation voltage (Uᵢ)
32 V
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
No-load supply current I0, typical
35 mA
Number of digital fail-safe inputs
2
Current, Utilisation category DC-12
0.05 A | 0.25 A
Current, Utilisation category DC-13
0.05 A | 0.25 A
Required rated short-circuit current
100A
Integral system diagnostics, status
Yes
Typical switching distance, frontal
12 mm
Typical switching distance, lateral
9 mm
Voltage, Utilisation category DC-12
24 VDC
Voltage, Utilisation category DC-13
24 VDC
Coding level according to EN ISO 14119
I1 variant: HighI2 variant: HighStandard coded variant: Low | High
Note (LED switching conditions display)
LED green: Supply voltage | LED red: Fault | LED yellow: Operating condition
Assured switching distance "ON", frontal
10 mm
Assured switching distance "ON", lateral
6 mm
Hysteresis (Switching distance), maximum
2 mm
Rated operating current (safety outputs)
250 mA
Assured switching distance "OFF", frontal
18 mm
Assured switching distance "OFF", lateral
15 mm
Monitoring function of downstream devices
Yes
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-28 °C
Output current, (fail-safe output), maximum
0.25 A
Tightening torque of the fixing screws, maximum
0.8 Nm
Number of semi-conductor outputs with signaling function
1
Permissible installation altitude above sea level, maximum
2,000 m
Safety Integrity Level (SIL), suitable for applications in
3
Input for enabling pushbutton, suitable for automatic start
Yes
Reaction time, switching off safety outputs via actuator, maximum
100 ms