Schmersal RSS260-I1-SD-ST
Order No 103003604
Certificates TÜV cULus FCC IC ANATEL
Schmersal System Solutions Series Diagnostic Systems

RSS260-I1-SD-ST Series Diagnostic Systems

Schmersal RSS260-I1-SD-ST features RFID working principle, IP65 IP67 protection class and -28 ... +65 °C ambient temperature.

Series: Sensors →

Product Description

  • • IP Rating: IP65/IP67
  • • Voltage: 24 VDC
  • • Weight: 54 g
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 61508

Product Features

  • • Individual coding with RFID technology
  • • High coding level according to ISO 14119
  • • 1 x connector plug M8
  • • Frontal and lateral actuation enabled
  • • Max. 31 sensors can be wired in series.
  • • Thermoplastic housing
  • • Simple mounting without additional angle
  • • RFID technology for demand-based tamper protection

Technical Specifications

PIN 1 A1 U e : White
PIN 2 X1 safety input 1: brown
PIN 3 A2 GND: Green
PIN 4 Y1 safety output 1: yellow
PIN 5 OUT serial diagnostic output: grey
PIN 6 X2 safety input 2: pink
PIN 7 Y2 safety output 2: blue
PIN 8 INPUT serial diagnostic input Pink
Mounting A screw length of 20 mm is generally sufficient for mounting the sensor. When mounting plates are used, we recommend 25 mm long screws.
Coding Individual coding
Category 4
Note (Sao) The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area lateral front
PFD Value 1.20 x 10⁻⁴
PFH value 6.80 x 10⁻¹⁰ /h
Number of LEDs 3
Number of Poles 8
Shock resistance 30 g / 11 ms
Mission time 20 Year(s)
Max. Hysteresis 2 mm
Serial Diagnostics Yes
Series Connection Yes
Gross weight 54 g
Housing Material Plastic, thermoplastic, self-extinguishing
Pollution degree 3
Max. Relative Humidity 93 %
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor length 29.5 mm
Scope of delivery Actuator must be ordered separately.
Vibration resistance 10 … 55 Hz, amplitude 1 mm
Cable Capacitance 50 nF
Max. Risk Time 200 ms
Sensor Topology Sensor for series connection
Operating current 150 mA
IP protection class IP65 IP67
Short-Circuit Detection Yes
Max. reaction time 100 ms
Ambient Temperature -28 ... +65 °C
Performance level e
RFID Frequency Band 125 kHz
Sensor width 39.2 mm
Operating voltage 24 VDC -15% / +10% (stabilised PELV power supply)
Working Principle RFID
Actuation Panels lateral, front side
Cascadable Yes
Housing Design Block
Sensor height 18 mm
Recommendation (Actuator) RST16-1 RST-U-2 RST260-1
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Fixing screw type 2x M4
Terminal connection Connector M8, 8-pole
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. installation altitude 2,000 m
Max. Test Pulse Duration 1 ms
Max. Ready Time 2,000 ms
Current Utilization Cat. DC-12 0.25 A
Current Utilization Cat. DC-13 0.25 A
Mechanical Mounting Conditions Non-flush
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage category III
Rated operating voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Serial Diagnostics (SD) Definition OUT
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 1 V
Max. Fixing Screw Torque 0.8 Nm
Max. Transmitter RFID Output -6 dBm
Number of Sensors Connected in Series 31
Rated impulse withstand voltage (Uimp) 0.8 kV
Control Elements Design short-circuit proof
Storage/transport temperature -28 ... +85 °C
Integrated System Diagnostics Status Yes
Coding level (EN ISO 14119) High
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 2 A
Rated insulation voltage (Uᵢ) 32 VDC
Max. Switching Frequency (Approx.) 1 Hz
Typical Lateral Switching Distance 9 mm
Typical Frontal Switching Distance 12 mm
Required rated short-circuit current 100A
Number of Safe Digital Outputs 2
ZVEI CB24I Sink Classification C1 C2
Safety Inputs Current Consumption 5 mA
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 35 mA
Max. Output Current (Safe Output) 0.25 A
Note (LED Switching Condition Indication) Yellow LED: operating status Green LED: supply voltage Red LED: fault
Guaranteed Open Lateral Switching Distance 6 mm
Guaranteed Open Frontal Switching Distance 10 mm
Guaranteed Closed Lateral Switching Distance 15 mm
Guaranteed Closed Frontal Switching Distance 18 mm
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms