Order No
103025103
Article Code
103025103
Certificates
TÜV cULus FCC IC ANATEL
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
RSS260-I2-D-LSTM12-5-0,25M
Product Description
- • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 121 g | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • 5-pole cable connector M12 for individual connection_x000D_
- • Repeated individual coding with RFID technology_x000D_
- • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
- • Simple mounting without additional angle_x000D_
- • Frontal and lateral actuation enabled_x000D_
- • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
- • Termoplastik gövde
Technical Specifications
PIN 1
A1 Supply voltage UB
PIN 2
Y2 Safety output 2
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUTPUT Diagnostics output
Mounting
20 mm screw length genellikle sensor mounted etmek for is sufficient. Mounting plates when used 25 mm in length screws we recommend.
Coding
Individual coding, multiple teaching
Category
4
Note (Sao)
The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area
lateral front
PFD Value
1.20 x 10⁻⁴
PFH Value
6.80 x 10⁻¹⁰ /h
Number of LEDs
3
Number of Poles
5
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Max. Hysteresis
2 mm
Series Connection
Yes
Gross Weight
121 g
Housing Material
Plastik, termoplastik, automatically fading
Pollution Degree
3
Max. Relative Humidity
0.93
Note (Relative Humidity)
Non-condensing, non-icing
Radiated Interference
IEC 61000-6-4
Sensor Length
29.5 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Max. Risk Time
200 ms
Sensor Topology
Series connection for sensor
Operating Current
50 mA
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
100 ms
Ambient Temperature
-28 ... +65 °C
Performance Level
e
RFID Frequency Band
125 kHz
Sensor Width
39.2 mm
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
RFID
Actuation Panels
lateral front taraf
Cascadable
Yes
Housing Design Form
Blok
Sensor Height
18 mm
Recommendation (Actuator)
RST16-1 RST-U-2 RST260-1
Repeat Accuracy R
0.5 mm
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output
Yes
Cross-Circuit Detection
Yes
Fixing Screw Type
2x M4
Terminal Connection
Connector M12, 5-pole, A-coded
Max. Leakage Current (Ir)
0.5 mA
Min. Operating Current
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Max. Installation Altitude
2,000 m
Max. Test Pulse Duration
1 ms
Max. Ready Time
2,000 ms
Current Utilization Cat. DC-12
0.05 A
Current Utilization Cat. DC-13
0.05 A
Utilization Category DC-12
24 VDC / 0.05 A
Mechanical Mounting Conditions
Embedded not
Min. Test Pulse Interval
100 ms
Note (Switching Distance)
All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R)
Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage Category
III
Rated Operating Voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Safety Inputs Definition
X1 and X2
Max. Voltage Drop (Ud)
2 V
Max. Fixing Screw Torque
0.8 Nm
Max. Transmitter RFID Output
-6 dBm
Impulse Withstand Voltage (Uimp)
0.8 kV
Control Elements Design
Short devre resistant, p-type
Storage/Transport Temperature
-28 ... +85 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
High
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Safety Outputs Definition
Y1 and Y2
Max. Electrical Fuse Rating
0.08333333333212067
Rated Insulation Voltage (Uᵢ)
32 VDC
Diagnostic Outputs Definition
OUT
Max. Switching Frequency (Approx.)
1 Hz
Typical Lateral Switching Distance
9 mm
Typical Frontal Switching Distance
12 mm
Required Rated Short-Circuit Current
100 A
Number of Safe Digital Outputs
2
ZVEI CB24I Sink Classification
C1 C2
Safety Inputs Current Consumption
5 mA
ZVEI CB24I Source Classification
C2
Typical Idle Operating Current (I₀)
35 mA
Max. Output Current (Safe Output)
0.25 A
Note (LED Switching Condition Indication)
Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Guaranteed Open Lateral Switching Distance
6 mm
Guaranteed Open Frontal Switching Distance
10 mm
Guaranteed Closed Lateral Switching Distance
15 mm
Guaranteed Closed Frontal Switching Distance
18 mm
Number of Semiconductor Outputs with Signal Function
1
Rated Operating Current (Safety Outputs)
250 mA
Max. Response Time (Actuator to Safety Output Off)
100 ms