Order No
103003607
Article Code
103003607
Certificates
TÜV cULus FCC IC ANATEL
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
RSS260-I2-D-ST
Product Description
- • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 61 g | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • Repeated individual coding with RFID technology_x000D_
- • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
- • 1 x connector plug M8_x000D_
- • Frontal and lateral actuation enabled_x000D_
- • Termoplastik gövde_x000D_
- • Simple mounting without additional angle_x000D_
- • İhtiyaca dayalı müdahale koruması için RFID teknolojisi
Technical Specifications
PIN 1
A1 U e : White
PIN 2
X1 safety input 1: Kahverengi
PIN 3
A2 GND: Green
PIN 4
Y1 safety output 1: Yellow
PIN 5
OUTPUT Diagnostics output OUT Grey
PIN 6
X2 safety input 2: Pembe
PIN 7
Y2 safety output 2: Mavi
PIN 8
Fonksiyonsuz INPUT: Red
Mounting
20 mm screw length genellikle sensor mounted etmek for is sufficient. Mounting plates when used 25 mm in length screws we recommend.
Coding
Individual coding, multiple teaching
Category
4
Note (Sao)
The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area
lateral front
PFD Value
1.20 x 10⁻⁴
PFH Value
6.80 x 10⁻¹⁰ /h
Number of LEDs
3
Number of Poles
8
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Max. Hysteresis
2 mm
Series Connection
Yes
Gross Weight
61 g
Housing Material
Plastik, termoplastik, automatically fading
Pollution Degree
3
Max. Relative Humidity
0.93
Note (Relative Humidity)
Non-condensing, non-icing
Radiated Interference
IEC 61000-6-4
Sensor Length
29.5 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Max. Risk Time
200 ms
Sensor Topology
Series connection for sensor
Operating Current
50 mA
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
100 ms
Ambient Temperature
-28 ... +65 °C
Performance Level
e
RFID Frequency Band
125 kHz
Sensor Width
39.2 mm
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
RFID
Actuation Panels
lateral front taraf
Cascadable
Yes
Housing Design Form
Blok
Sensor Height
18 mm
Recommendation (Actuator)
RST16-1 RST-U-2 RST260-1
Repeat Accuracy R
0.5 mm
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Diagnostic Output
Yes
Cross-Circuit Detection
Yes
Fixing Screw Type
2x M4
Terminal Connection
Connector M8, 8-pole
Max. Leakage Current (Ir)
0.5 mA
Min. Operating Current
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Max. Installation Altitude
2,000 m
Max. Test Pulse Duration
1 ms
Max. Ready Time
2,000 ms
Current Utilization Cat. DC-12
0.05 A
Current Utilization Cat. DC-13
0.05 A
Utilization Category DC-12
24 VDC / 0.05 A
Mechanical Mounting Conditions
Embedded not
Min. Test Pulse Interval
100 ms
Note (Switching Distance)
All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R)
Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage Category
III
Rated Operating Voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Safety Inputs Definition
X1 and X2
Max. Voltage Drop (Ud)
2 V
Max. Fixing Screw Torque
0.8 Nm
Max. Transmitter RFID Output
-6 dBm
Impulse Withstand Voltage (Uimp)
0.8 kV
Control Elements Design
Short devre resistant, p-type
Storage/Transport Temperature
-28 ... +85 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
High
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition
Y1 and Y2
Max. Electrical Fuse Rating
0.08333333333212067
Rated Insulation Voltage (Uᵢ)
32 VDC
Diagnostic Outputs Definition
OUT
Max. Switching Frequency (Approx.)
1 Hz
Typical Lateral Switching Distance
9 mm
Typical Frontal Switching Distance
12 mm
Required Rated Short-Circuit Current
100 A
Number of Safe Digital Outputs
2
ZVEI CB24I Sink Classification
C1 C2
Safety Inputs Current Consumption
5 mA
ZVEI CB24I Source Classification
C2
Typical Idle Operating Current (I₀)
35 mA
Max. Output Current (Safe Output)
0.25 A
Note (LED Switching Condition Indication)
Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Guaranteed Open Lateral Switching Distance
6 mm
Guaranteed Open Frontal Switching Distance
10 mm
Guaranteed Closed Lateral Switching Distance
15 mm
Guaranteed Closed Frontal Switching Distance
18 mm
Number of Semiconductor Outputs with Signal Function
1
Rated Operating Current (Safety Outputs)
250 mA
Max. Response Time (Actuator to Safety Output Off)
100 ms