RSS260-I2-LSTM12-5-0,25M
Order No 103015321
Article Code 103015321
Certificates TÜV cULus FCC IC ANATEL
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

RSS260-I2-LSTM12-5-0,25M

Product Description

  • • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 121 g | PL e

Standards

  • • EN ISO 13849-1 EN IEC 61508

Product Features

  • • 5-pole cable connector M12 for individual connection_x000D_
  • • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
  • • Simple mounting without additional angle_x000D_
  • • Individual coding with RFID technology_x000D_
  • • Frontal and lateral actuation enabled_x000D_
  • • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
  • • Termoplastik gövde

Technical Specifications

PIN 1 A1 Supply voltage UB
PIN 2 Y2 Safety output 2
PIN 3 A2 GND
PIN 4 Y1 Safety output 1
PIN 5 n.c.
Mounting 20 mm screw length genellikle sensor mounted etmek for is sufficient. Mounting plates when used 25 mm in length screws we recommend.
Coding Individual coding, multiple teaching
Category 4
Note (Sao) The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area lateral front
PFD Value 1.20 x 10⁻⁴
PFH Value 6.80 x 10⁻¹⁰ /h
Number of LEDs 3
Number of Poles 5
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Max. Hysteresis 2 mm
Series Connection Yes
Gross Weight 121 g
Housing Material Plastik, termoplastik, automatically fading
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Radiated Interference IEC 61000-6-4
Sensor Length 29.5 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 55 Hz, amplitude 1 mm
Max. Risk Time 200 ms
Sensor Topology Series connection for sensor
Operating Current 50 mA
IP Protection Class IP65 IP67
Short-Circuit Detection Yes
Max. Response Time 100 ms
Ambient Temperature -28 ... +65 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 39.2 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Actuation Panels lateral front taraf
Cascadable Yes
Housing Design Form Blok
Sensor Height 18 mm
Recommendation (Actuator) RST16-1 RST-U-2 RST260-1
Repeat Accuracy R 0.5 mm
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Fixing Screw Type 2x M4
Terminal Connection Connector M12, 5-pole, A-coded
Max. Leakage Current (Ir) 0.5 mA
Min. Operating Current 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Test Pulse Duration 1 ms
Max. Ready Time 2,000 ms
Current Utilization Cat. DC-12 0.05 A
Current Utilization Cat. DC-13 0.05 A
Utilization Category DC-12 24 VDC / 0.05 A
Mechanical Mounting Conditions Embedded not
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R) Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage Category III
Rated Operating Voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 2 V
Max. Fixing Screw Torque 0.8 Nm
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Control Elements Design Short devre resistant, p-type
Storage/Transport Temperature -28 ... +85 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) High
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Safety Outputs Definition Y1 and Y2
Max. Electrical Fuse Rating 0.08333333333212067
Rated Insulation Voltage (Uᵢ) 32 VDC
Diagnostic Outputs Definition OUT
Max. Switching Frequency (Approx.) 1 Hz
Typical Lateral Switching Distance 9 mm
Typical Frontal Switching Distance 12 mm
Required Rated Short-Circuit Current 100 A
Number of Safe Digital Outputs 2
ZVEI CB24I Sink Classification C1 C2
Safety Inputs Current Consumption 5 mA
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 35 mA
Max. Output Current (Safe Output) 0.25 A
Note (LED Switching Condition Indication) Yellow LED: Operation status Green LED: Supply voltage Red LED: Fault
Guaranteed Open Lateral Switching Distance 6 mm
Guaranteed Open Frontal Switching Distance 10 mm
Guaranteed Closed Lateral Switching Distance 15 mm
Guaranteed Closed Frontal Switching Distance 18 mm
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms