Order No
103003605
Certificates
TÜV cULus FCC IC ANATEL
Schmersal
System Solutions
Series Diagnostic Systems
RSS260-SD-ST Series Diagnostic Systems
Schmersal RSS260-SD-ST features RFID working principle, IP65 IP67 protection class and -28 ... +65 °C ambient temperature.
Product Description
- • IP Rating: IP65/IP67
- • Voltage: 24 VDC
- • Weight: 61 g
- • PL e
Standards
- • EN ISO 13849-1
- • EN IEC 61508
Product Features
- • Universal coding with RFID technology
- • 1 x connector plug M8
- • Frontal and lateral actuation enabled
- • Max. 31 sensors can be wired in series.
- • Thermoplastic housing
- • Simple mounting without additional angle
- • RFID technology for demand-based tamper protection
Technical Specifications
PIN 1
A1 U e : White
PIN 2
X1 safety input 1: brown
PIN 3
A2 GND: Green
PIN 4
Y1 safety output 1: yellow
PIN 5
OUT serial diagnostic output: grey
PIN 6
X2 safety input 2: pink
PIN 7
Y2 safety output 2: blue
PIN 8
INPUT serial diagnostic input Pink
Mounting
A screw length of 20 mm is generally sufficient for mounting the sensor. When mounting plates are used, we recommend 25 mm long screws.
Coding
Universal coding
Category
4
General note
Evaluation requirements: two-channel safety input, suitable for p-switching sensors with NO function.
Note (Sao)
The safety switching distance Sao specifications refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
Active Area
lateral front
PFD Value
1.20 x 10⁻⁴
PFH value
6.80 x 10⁻¹⁰ /h
Number of LEDs
3
Number of Poles
8
Shock resistance
30 g / 11 ms
Mission time
20 Year(s)
Max. Hysteresis
2 mm
Serial Diagnostics
Yes
Series Connection
Yes
Gross weight
61 g
Housing Material
Plastic, thermoplastic, self-extinguishing
Pollution degree
3
Max. Relative Humidity
93 %
Note (Relative Humidity)
Non-condensing, non-icing
Radiated Interference
IEC 61000-6-4
Sensor length
29.5 mm
Scope of delivery
Actuator must be ordered separately.
Vibration resistance
10 … 55 Hz, amplitude 1 mm
Cable Capacitance
50 nF
Max. Risk Time
200 ms
Sensor Topology
Sensor for series connection
Operating current
150 mA
IP protection class
IP65 IP67
Short-Circuit Detection
Yes
Max. reaction time
100 ms
Ambient Temperature
-28 ... +65 °C
Performance level
e
RFID Frequency Band
125 kHz
Sensor width
39.2 mm
Operating voltage
24 VDC -15% / +10% (stabilised PELV power supply)
Working Principle
RFID
Actuation Panels
lateral, front side
Cascadable
Yes
Housing Design
Block
Sensor height
18 mm
Recommendation (Actuator)
RST16-1 RST-U-2 RST260-1
Repeat Accuracy R
0.5 mm
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection
Yes
Fixing screw type
2x M4
Terminal connection
Connector M8, 8-pole
Max. Leakage Current (Ir)
0.5 mA
Min. Operating Current
0.5 mA
Suitable SIL Applications
3
Safety Functions
Yes
Max. installation altitude
2,000 m
Max. Test Pulse Duration
1 ms
Max. Ready Time
2,000 ms
Current Utilization Cat. DC-12
0.25 A
Current Utilization Cat. DC-13
0.25 A
Mechanical Mounting Conditions
Non-flush
Min. Test Pulse Interval
100 ms
Note (Switching Distance)
All switching distances are per the EN IEC 60947-5-3 standard. Axial misalignment is tolerated. The possible misalignment depends on the distance between the active surfaces. The sensor remains active within the tolerance range.
Note (Repeat Accuracy R)
Axial offset: the long edge allows a maximum height misalignment of 8 mm between the sensor and the actuator. Axial misalignment (y) max. ±18 mm. Minimum distance of 100 mm between two sensor systems
Overvoltage category
III
Rated operating voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Serial Diagnostics (SD) Definition
OUT
Safety Inputs Definition
X1 and X2
Max. Voltage Drop (Ud)
1 V
Max. Fixing Screw Torque
0.8 Nm
Max. Transmitter RFID Output
-6 dBm
Number of Sensors Connected in Series
31
Rated impulse withstand voltage (Uimp)
0.8 kV
Control Elements Design
short-circuit proof
Storage/transport temperature
-28 ... +85 °C
Integrated System Diagnostics Status
Yes
Coding level (EN ISO 14119)
Low
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Recommended Safety Switch
PROTECT PSC1 SRB-E-301ST SRB-E-201LC
Safety Outputs Definition
Y1 and Y2
Max. Electrical Fuse Rating
2 A
Rated insulation voltage (Uᵢ)
32 VDC
Max. Switching Frequency (Approx.)
1 Hz
Typical Lateral Switching Distance
9 mm
Typical Frontal Switching Distance
12 mm
Required rated short-circuit current
100A
Number of Safe Digital Outputs
2
ZVEI CB24I Sink Classification
C1 C2
Safety Inputs Current Consumption
5 mA
ZVEI CB24I Source Classification
C2
Typical Idle Operating Current (I₀)
35 mA
Max. Output Current (Safe Output)
0.25 A
Note (LED Switching Condition Indication)
Yellow LED: operating status Green LED: supply voltage Red LED: fault
Guaranteed Open Lateral Switching Distance
6 mm
Guaranteed Open Frontal Switching Distance
10 mm
Guaranteed Closed Lateral Switching Distance
15 mm
Guaranteed Closed Frontal Switching Distance
18 mm
Rated Operating Current (Safety Outputs)
250 mA
Max. Response Time (Actuator to Safety Output Off)
100 ms