Schmersal SD-I-DP-V0-2 PROFIBUS-GATEWAY
Order No 101192805
Schmersal System Solutions Series Diagnostic Systems

SD-I-DP-V0-2 PROFIBUS-GATEWAY Series Diagnostic Systems

Schmersal SD-I-DP-V0-2 PROFIBUS-GATEWAY features -5 ... +55 °C ambient temperature, cage clamps terminal connection, 97 mm depth and 50 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 50mm×72mm×97mm
  • • Weight: 120 g

Product Features

  • • PROFIBUS Gateway SD-I-DP-V0-2 to convert serial diagnostic signals to the PROFIBUS DP protocol
  • • The PROFIBUS Gateway SD-I-DP-V0-2 is a PROFIBUS slave
  • • Protection class IP 10 device for control cabinet mounting, for standard DIN rails

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 97 mm
General note For detailed functions, see the SD Gateway programming and configuration manual
Width 50 mm
Height 72 mm
Number of LEDs 4
Shock resistance 15 g / 11 ms
Application Note Safety sensor, guard system
Gross weight 120 g
Pollution degree 2
Vibration resistance 5 ... 9 Hz, amplitude 3,5 mm 9 ... 150 Hz, at 1 g
Operating current 250 mA
Ambient Temperature -5 ... +55 °C
Operating voltage 24 VDC -15 % / +20 %
IP Protection (Housing) IP10
Terminal connection Cage clamps
Connection Diagram Note Serial diagnostics of series-connected safety sensors/solenoid locks. Devices with a serial diagnostics option: AZ 200, AZM 200, CSS 30S, CSS 34, MZM 100
Overvoltage category II
Rated operating voltage 24 VDC
Rated impulse withstand voltage (Uimp) 0.5 kV
Storage/transport temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Rated insulation voltage (Uᵢ) 32 V
Note (LED Switching Condition Indication) ON continuous green light: supply voltage present PB flashing signal: PROFIBUS start-up PB continuous red light: PROFIBUS error SD flashing signal: = SD gateway start-up SD continuous red light: = SD gateway...