Order No
101209435
Certificates
cULus
Schmersal
System Solutions
Series Diagnostic Systems
SD-I-U-CCL Series Diagnostic Systems
Schmersal SD-I-U-CCL features +0 ... +55 °C ambient temperature, cage clamps terminal connection, 80 mm depth and 50 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 50mm×100mm×80mm
- • Weight: 200 g
Product Features
- • UNIVERSAL Gateway for the series-wiring of the diagnostic signals of safety switchgear with integrated SD interface.
- • Comprehensive volumes of status and diagnostic data of the SD devices are transmitted to the control system through the field bus interface.
- • Series-wiring of the diagnostic lines of max. 31 safety switchgear
- • Series-wiring of different devices possible
- • Reduced wiring efforts and costs as a result of the series-wiring of the safety channels and the diagnostic cables in the field.
- • Automatic addressing of the safety switchgear in the SD interface
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Depth
80 mm
Width
50 mm
Height
100 mm
Number of LEDs
1
Shock resistance
10 g
EMC Class
EN 61000-4-3 EN 61000-4-6
Application Note
Safety sensor, guard system
Gross weight
200 g
Min. Relative Humidity
30 %
Pollution degree
2
Max. Relative Humidity
85 %
Note (Relative Humidity)
Non-condensing
Radiated Interference
IEC 61000-6-4 (2002)
Vibration resistance
10 ... 57 Hz, amplitude 0,35 mm 57 ... 150 Hz, at 5 g
Operating current
500 mA
Fieldbus Protocol
CC-Link
Ambient Temperature
+0 ... +55 °C
Operating voltage
24 VDC -15 % / +20 %
IP Protection (Housing)
IP20
Terminal connection
Cage clamps
Electromagnetic Compatibility
EN 61000-4-2 EN 61000-4-4 EN 61000-4-5
Overvoltage category
II
Rated operating voltage
24 VDC
Rated impulse withstand voltage (Uimp)
0.5 kV
Storage/transport temperature
-25 ... +75 °C
Integrated System Diagnostics Status
Yes
Rated insulation voltage (Uᵢ)
32 V