Schmersal SE-100 C EVALUATION UNIT features cam elyaf termoplastik housing material, +5 ... +55 °C ambient temperature, 121 mm depth and 22.5 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×100mm×121mm
- • Weight: 166 g
- • Cable: 200 m
- • PL c
Standards
- • EN ISO 13849-1
- • EN ISO 13850
Product Features
- • To monitor 1 ... 2 safety edge(s)
- • 1 safety contact, STOP 0
- • 1 signal output
Technical Specifications
Note
All specifications include conductor ferrules.
Mounting
Fits onto a standard DIN rail per EN 60715
Depth
121 mm
Category
1
General note
Overall machine safety depends on professional installation of the safety monitoring module and signal transmitter, and correct electrical connection. The machine must not be restarted if any risk exists.
Width
22.5 mm
Height
100 mm
PFH value
2.24 x 10⁻⁶ /h
Number of LEDs
2
EMC Class
EMC Directive
Application Note
Safety edges
Mission time
20 Year(s)
Cable length
200 m
Gross weight
166 g
Housing Material
Glass-fibre thermoplastic
Pollution degree
2
Note (PFH Value)
up to max. 5,000 switching cycles/year
Vibration resistance
10 … 55 Hz, amplitude 0.15 mm
Electronic Fuse
Yes
Max. cable cross-section
2 x 1.5 mm²
Terminal (Mechanical)
Screw terminals
Operating current
150 mA
Climatic Resistance
EN ISO 13856-2
Stop Category
0
Max. reaction time
16 ms
Ambient Temperature
+5 ... +55 °C
Performance level
c
Operating voltage
24 VDC -10 % / +20 %
IP Protection (Housing)
IP40
Mechanical life (min.)
20,000,000 Cycles
Reset When Power is Removed
Yes
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Connection Diagram Note
Monitoring of SE 40 / SE 70 safety edges with the SE-100C safety monitoring unit up to PL c and Category.
Number of safety contacts
1
IP Protection (Mounting Area)
IP54
Max. Ready Time
300 ms
Automatic Reset Function
Yes
Control Category (EN954)
1
Utilization Category AC-15
2 A
Utilization Category DC-13
2 A
Number of auxiliary contacts
1
Overvoltage category
III
Rated operating voltage
24 VDC
Number of Signal Outputs
1
IP Protection (Terminal Block)
IP20
Earth Connection Detection
Yes
Rated impulse withstand voltage (Uimp)
4 kV
Integrated System Diagnostics Status
Yes
DC Min. Rated Control Voltage
21.6 VDC
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Safety edge function
Max. Electrical Power Consumption
4 W