Schmersal SE-400 C EVALUATION UNIT
Order No 101153920
Certificates TÜV cULus
Schmersal Safe Switching and Monitoring Safety Tactile Sensors

SE-400 C EVALUATION UNIT Safety Tactile Sensors

Schmersal SE-400 C EVALUATION UNIT features cam elyaf termoplastik housing material, +5 ... +55 °C ambient temperature, 121 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×100mm×121mm
  • • Weight: 184 g
  • • Cable: 200 m
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN ISO 13850

Product Features

  • • To monitor 1 safety edge(s)
  • • 2 safety contacts, STOP 0
  • • 1 signal output

Technical Specifications

Note All specifications include conductor ferrules.
Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
Category 4
General note Overall machine safety depends on professional installation of the safety monitoring module and signal transmitter, and correct electrical connection. The machine must not be restarted if any risk exists.
Width 22.5 mm
Height 100 mm
PFH value 2.47 x 10⁻⁸ /h
Number of LEDs 2
EMC Class EMC Directive
Application Note Safety edges
Mission time 20 Year(s)
Cable length 200 m
Gross weight 184 g
Housing Material Glass-fibre thermoplastic
Start Input Yes
Pollution degree 2
Note (PFH Value) up to max. 50,000 switching cycles/year
Vibration resistance 10 … 55 Hz, amplitude 0.15 mm
Electronic Fuse Yes
Max. cable cross-section 2 x 1.5 mm²
Terminal (Mechanical) Screw terminals
Operating current 150 mA
Climatic Resistance EN ISO 13856-2
Stop Category 0
Max. reaction time 32 ms
Ambient Temperature +5 ... +55 °C
Performance level e
Reset Edge Detection Yes
Operating voltage 24 VDC -10 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Mechanical life (min.) 30,000,000 Cycles
Reset When Power is Removed Yes
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Connection Diagram Note The start/reset button (S) can optionally be connected to the feedback circuit. Both restart types must comply with the requirements of EN 1760-2.
Number of safety contacts 2
IP Protection (Mounting Area) IP54
Max. Ready Time 32 ms
Automatic Reset Function Yes
Control Category (EN954) 4
Utilization Category AC-15 3 A
Utilization Category DC-13 1 A
Overvoltage category III
Rated operating voltage 24 VDC
Number of Signal Outputs 1
IP Protection (Terminal Block) IP20
Earth Connection Detection Yes
Rated impulse withstand voltage (Uimp) 4 kV
Integrated System Diagnostics Status Yes
DC Min. Rated Control Voltage 21.6 VDC
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Safety edge function
Max. Electrical Power Consumption 4 W
Number of Undelayed Semiconductor Outputs (with Signal Function) 1