SLC 220-E/R1075-30-69-RFB-H
Order No 101206528
Certificates cULus
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SLC 220-E/R1075-30-69-RFB-H

SLC 220-E/R1075-30-69-RFB-H — Schmersal product. Key specifications: Housing Material: Aluminium; IP protection class: IP65; Ambient Temperature: -10 ... +50 °C; Sensor height: 1,129 mm; PFH value: 3.59 x 10⁻⁷ /h. Article number: 101206528. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP65
  • • Ağırlık: 5,180 g
  • • Sertifika: cULus

Standards

  • • EN IEC 61496-1
  • • EN IEC 61508
  • • EN IEC 61496-2
  • • EN ISO 13849-1

Product Features

  • • Protection class IP65
  • • Safety type 2 in accordance with IEC 61496-1
  • • Resolution 30 and 80 mm
  • • Protection field height from 175 mm … 1675 mm

Technical Specifications

Category 2
General note Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.
PFH value 3.59 x 10⁻⁷ /h
Mission time 20 Year(s)
Net Ağırlık 5,180 g
Bağlantı Tipi Connector
Length of cable 5 m
Number of beams 42
Gross weight 5,180 g
Housing Material Aluminium
Protection class III
Blanking function Yes
Scope of delivery Emitter + receiver, mounting angle
Diameter of sensor 60 mm
IP protection class IP65
Ambient Temperature -10 ... +50 °C
Performance level d
Sensor height 1,129 mm
Tolerance, percentage 20 %
Reaction time, maximum 30 ms
Min. Ortam Sıcaklığı -10 °C
Note (Delivery capacity) Not available!
Maks. Ortam Sıcaklığı +50 °C
Design of control elements p-type
Integral system diagnostics Yes
Recommended safety switchgear SCR 211
Terminal connector, Recipient Cable with connector plug M12, 8-pole
Wave length of the laserdiode 880 nm
Height of the protection field 1,075 mm
Range, protection field, maximum 14 m
Range, protection field, minimum 4 m
Restart interlock (manual reset) Yes
Terminal, Connector, Transmitter Cable with connector plug M12, 8-pole
Depolama / Taşıma Sıcaklığı -20 ... +70 °C
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Switching voltage OSSD, HIGH signal 24 V
Protection class (Operating resource) 3
Length of the connectable cable, maximum 100 m
Safety type in accordance with IEC 61496-1 2
Storage and transport temperature, maximum +70 °C
Storage and transport temperature, minimum -20 °C
Output current, (fail-safe output), maximum 0.2 A
Electrical power consumption of the receiver 8 W
Electrical power consumption of the transmitter 4 W
Detection ability for test bodies at v = 1.6 m/s 30 mm
Safety Integrity Level (SIL), suitable for applications in 2