Order No
101186020
Certificates
TÜV
Schmersal
Safe Switching and Monitoring
Emniyet Konum Şalterleri (PS Serisi)
SLC 410-E/R0760-14-BM
SLC 410-E/R0760-14-BM — Schmersal product. Key specifications: Housing Material: Aluminium; IP protection class: IP65; Ambient Temperature: +0 ... +55 °C; Sensor length: 35 mm; Sensor width: 45 mm. Article number: 101186020. Request a quote for pricing and lead time; technical data and documents are listed below.
Product Description
- • IP: IP65
- • Sertifika: TÜV
Standards
- • EN IEC 61496-1
- • EN IEC 61496-2
Product Features
- • NOTICE: Not available! (Replacement: SLC 420)
- • Control Category 4
Technical Specifications
General note
The SLC 410 BM Master can be combined with all slaves of the SLC 410...RFS series.
Cascadable
Yes
Bağlantı Tipi
Connector
Number of beams
75
Housing Material
Aluminium
Protection class
III
Blanking function
Yes
Scope of delivery
Emitter + receiver, mounting angle, T-slot nuts
Sensor length
35 mm
IP protection class
IP65
Ambient Temperature
+0 ... +55 °C
Sensor width
45 mm
Sensor height
861 mm
Beam coding available
Yes
Tolerance, percentage
20 %
Reaction time, maximum
19.5 ms
Min. Ortam Sıcaklığı
+0 °C
Note (Delivery capacity)
Not available!
Maks. Ortam Sıcaklığı
+55 °C
Master- or Slave-function
master
Design of control elements
p-type
Integral system diagnostics
Yes
Recommended safety switchgear
SCR 402R-301
Terminal connector, Recipient
Connector plug M12, 8-pole
Wave length of the laserdiode
950 nm
Height of the protection field
760 mm
Range, protection field, maximum
5 m
Range, protection field, minimum
0 m
Terminal, Connector, Transmitter
Connector plug M12, 5-pole
Depolama / Taşıma Sıcaklığı
-20 ... +70 °C
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Switching voltage OSSD, HIGH signal
24 V
Cable length (Master/Slave), maximum
50 m
Protection class (Operating resource)
3
Length of the connectable cable, maximum
100 m
Safety type in accordance with IEC 61496-1
4
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-20 °C
Output current, (fail-safe output), maximum
0.5 A
Electrical power consumption of the receiver
3 W
Electrical power consumption of the transmitter
2 W
Detection ability for test bodies at v = 1.6 m/s
14 mm