Note
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. | Reduction in range by 10% at an ambient temperature of -25°C | signal transmission in case of falling edge | The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). | According to EN 61131-2
PIN 1
Release/restart interlock Acknowledgement restart interlock | 24 VDC power supply
PIN 2
24 VDC power supply | COD1 Coding 1
PIN 3
OSSD 1 Safety output 1 | 0 VDC power supply
PIN 4
COD2 Coding 2 | OSSD 2 Safety output 2
PIN 5
Restart 2 Acknowledgement restart interlock 2
PIN 6
DOUT Operating Mode
PIN 7
0 VDC power supply
PIN 8
Contactor control Input EDM
CADENAS
Yes
Category
4
Bluetooth
Yes
PFH value
5.14 x 10⁻⁹ /h
Connection
Emitter | Receiver
LED status
transmitting and status | OSSD ON, OSSD OFF, restart, signal reception, blanking, information, Bluetooth
LED position
Emitter | Receiver
Shock resistance
10 g, 16 ms, to EN 60028-2-29
Mission time
20 Year(s)
Bağlantı Tipi
Connector
Number of beams
32
Housing Material
Aluminium
Protection class
III
7-segment display
Yes
Blanking function
Yes
Operating voltage
24 VDC -10 % / +10 % ((PELV) supply unit Imax 2.0 A, according to EN 60204 (power failure ≤ 20 ms))
Scope of delivery
Kit with 2 mounting angles
Sensor length
33 mm
Switching voltage
0 … 2 V (LOW) | 15 … 26.4 V (HIGH)
Vibration resistance
10 … 55 Hz
Height of Receiver
421 mm
Current consumption
0 … 2 mA (LOW) | 3 … 10 mA (HIGH)
IP protection class
IP67
Ambient Temperature
-25 ... +50 °C
Performance level
e
Sensor width
27.8 mm
Switching thresholds
11 … 30 V (HIGH) | 0 … 2 V (LOW)
Beam coding available
Yes
Height of transmitter
411 mm
Tolerance, percentage
10 %
Load capacity, maximum
2.2 µF
Reaction time, maximum
10 ms
Terminal connection
with metal thread
Note (Software Version)
as of 2021 Version 3.1
Load inductance, maximum
2 H
Min. Ortam Sıcaklığı
-25 °C
Maks. Ortam Sıcaklığı
+50 °C
Design of control elements
OSSD, short-circuit proof, p-type
Designation, Control inputs
Release/restart and Restart 2
Designation, Safety outputs
OSSD 1 and OSSD 2
Integral system diagnostics
Yes
Leakage current Ir, maximum
1 mA
Nominal Çalışma Voltajı
24 VDC
Contactor control integrated
Yes
Test pulse duration, maximum
0.1 ms
Test pulse interval, typical
750 ms
Note (application conditions)
automatic mode, restart interlock, double reset, contactor control, beam blanking fixed and floating, beam coding A
Recommended safety switchgear
SRB-E 301
Terminal connector, Recipient
Connector plug M12, 8-pole
Wave length of the laserdiode
850 nm
Conduction resistance, maximum
2.5 Ω
Height of the protection field
330 mm
Actuation time for manual start
50 … 1500 ms
Classification ZVEI CB24I, Sink
C1 | C3 | C2
Bluetooth transmission frequency
2.400 … 2.483 GHz
Range, protection field, maximum
10 m
Range, protection field, minimum
3 m
Rated operating current, Emitter
200 mA
Restart interlock (manual reset)
Yes
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Classification ZVEI CB24I, Source
C3
Depolama / Taşıma Sıcaklığı
-25 ... +70 °C | -25 ... +75 °C
Rated operating current, Receiver
700 mA
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Bluetooth transmission power, maximum
2 µW
Protection class (Operating resource)
3
Radiation emission level to EN 12198-1
Category 0
Height of the protection field, minimum
3 mm
Length of the connectable cable, maximum
100 m
Safety type in accordance with IEC 61496-1
4
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Reaction time of the external devices, maximum
500 ms
Detection ability for test bodies at v = 1.6 m/s
14 mm
Risk group classification of lamp systems to EN 62471
free group
Designation, Contactor controls EDM (Feedback circuits)
Contactor control
Safety Integrity Level (SIL), suitable for applications in
3