Note
In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. | The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). | According to EN 61131-2
PIN 1
24 VDC power supply
PIN 2
OSSD 1 Safety output 1 | Do not connect a signal (do not wire)
PIN 3
0 VDC power supply | 0 VDC Power supply
PIN 4
Do not connect a signal (do not wire) | OSSD 2 Safety output 2
PIN 5
Release/restart interlock Acknowledgement restart interlock
CADENAS
Yes
Category
4
PFH value
8.05 x 10⁻⁹ /h
Connection
Emitter | Receiver
LED status
transmitting and status | OSSD ON, OSSD OFF, Restart interlock, Error, Parameter setting, Alignment kit, Indication of signal quality
Traceparts
Yes
LED position
Emitter | Receiver
Shock resistance
Class 3M4, 15 g, 6 ms, IEC 60068-2-27
Mission time
20 Year(s)
Net Ağırlık
700 g
Bağlantı Tipi
Connector
Number of beams
20
Gross weight
700 g
Housing Material
Aluminium
Protection class
III
Operating voltage
24 VDC -20 % / +20 % ((PELV) supply unit Imax 1.0 A, according to EN 60204 (power failure ≤ 20 ms))
Scope of delivery
Kit | Mounting kit MS-1100
Sensor length
33 mm
Switching voltage
0 … 2 V (LOW) | 15 … 26.4 V (HIGH)
Vibration resistance
Class 3M4, 5...150 Hz, IEC 60068-2-6
IP protection class
IP67
Ambient Temperature
-10 ... +50 °C
Performance level
e
Sensor width
27.8 mm
Sensor height
451 mm
Tolerance, percentage
10 %
Load capacity, maximum
0.05 µF
Reaction time, maximum
10 ms
Note (Software Version)
as of 2026 Version 4.0
Load inductance, maximum
2 H
Min. Ortam Sıcaklığı
-10 °C
Maks. Ortam Sıcaklığı
+50 °C
Design of control elements
OSSD, short-circuit proof, p-type
Designation, Control inputs
Release / restart interlock
Designation, Safety outputs
OSSD 1 and OSSD 2
Integral system diagnostics
Yes
Leakage current Ir, maximum
1 mA
Nominal Çalışma Voltajı
24 VDC
Test pulse duration, maximum
0.15 ms
Test pulse interval, typical
750 ms
Note (application conditions)
protective mode/automatic, restart interlock, setting mode
Recommended safety switchgear
SRB-E 301
Terminal connector, Recipient
Connector plug M12, 5-pole
Wave length of the laserdiode
850 nm
Height of the protection field
410 mm
Actuation time for manual start
100 … 1500 ms
Classification ZVEI CB24I, Sink
C1 | C2
Bluetooth transmission frequency
2.400 … 2.483 GHz
Range, protection field, maximum
30 m
Range, protection field, minimum
8 m
Rated operating current, Emitter
200 mA
Restart interlock (manual reset)
Yes
Terminal, Connector, Transmitter
Connector plug M12, 4-pole
Classification ZVEI CB24I, Source
C2
Depolama / Taşıma Sıcaklığı
-25 ... +75 °C | -25 ... +70 °C
Rated operating current, Receiver
700 mA
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Bluetooth transmission power, maximum
2 µW
Protection class (Operating resource)
3
Radiation emission level to EN 12198-1
Category 0
Length of the connectable cable, maximum
100 m
Safety type in accordance with IEC 61496-1
4
Storage and transport temperature, maximum
+70 °C
Storage and transport temperature, minimum
-25 °C
Output current, (fail-safe output), maximum
0.25 A
Detection ability for test bodies at v = 1.6 m/s
30 mm
Risk group classification of lamp systems to EN 62471
free group
Safety Integrity Level (SIL), suitable for applications in
3