SLC445-ER-1130-14-01
Order No 103005398
Certificates cULus TÜV
Schmersal Safe Switching and Monitoring Emniyet Işık Perdeleri ve Izgaraları

SLC445-ER-1130-14-01

SLC445-ER-1130-14-01 — Schmersal product. Key specifications: Housing Material: Aluminium; IP protection class: IP67; Ambient Temperature: -25 ... +50 °C; Terminal connection: with metal thread; Sensor length: 33 mm. Article number: 103005398. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • IP: IP67
  • • Ağırlık: 1,980 g
  • • Sertifika: cULus TÜV

Standards

  • • CLC/TS 61496-2
  • • EN IEC 61496-1
  • • EN ISO 13849-1
  • • EN IEC 62061

Product Features

  • • Multifunctional
  • • Muting
  • • Cyclic mode
  • • Double acknowledgement/reset
  • • Multiscan
  • • Safety type 4 in accordance with IEC 61496-1
  • • active integrated set-up tool
  • • Blanking: fixed/floating
  • • Status and diagnostics via 7-segment display
  • • Integrated contactor control
  • • User-friendly parameter setting, no tools required

Technical Specifications

Note In case of failure, the leakage current flows to the OSSD cable. The downstream control element must recognise this state as LOW. A safety PLC must detect this state. | Reduction in range by 10% at an ambient temperature of -25°C | signal transmission in case of falling edge | The load inductance generates an induced voltage during the switch-off, which compromises the downstream components (sparkquenching element). | According to EN 61131-2
EPLAN Yes
PIN 1 24 VDC power supply
PIN 2 0 VDC power supply | COD1 Coding 1
PIN 3 0 VDC power supply | Release S1 Input Release S1
PIN 4 COD2 Coding 2 | OSSD 1 Safety output 1
PIN 5 D_OUT Operating Mode
PIN 6 OSSD 2 Safety output 2
PIN 7 Muting operation: ML Muting lampCyclic mode: not used
PIN 8 Input Release S2
PIN 9 Muting operation: D_IN Input EDM, belt-stop, muting enableCyclic mode: D_IN Input EDM
PIN 10 Muting operation: MSG 2 Switching input muting sensor group MSG 2Cyclic mode: MK2 Machine contact 2
PIN 11 Not used
PIN 12 Muting operation: MSG 1 Switching input muting sensor group MSG 1Cyclic mode: MK1 Machine contact 1
CADENAS Yes
Category 4
Override Yes
PFH value 5.14 x 10⁻⁹ /h
Connection Emitter | Receiver
LED status OSSD ON, OSSD OFF, restart, signal reception, blanking, information | transmitting and status
Traceparts Yes
LED position Emitter | Receiver
Shock resistance 10 g, 16 ms, to EN 60028-2-29
Mission time 20 Year(s)
Net Ağırlık 1,980 g
Bağlantı Tipi Connector
Muting function Yes
Number of beams 112
Gross weight 1,980 g
Housing Material Aluminium
Protection class III
7-segment display Yes
Blanking function Yes
Operating voltage 24 VDC -10 % / +10 % ((PELV) supply unit Imax 2.0 A, according to EN 60204 (power failure ≤ 20 ms))
Scope of delivery Kit with 2 mounting angles
Sensor length 33 mm
Switching voltage 0 … 2 V (LOW) | 15 … 26.4 V (HIGH)
Vibration resistance 10 … 55 Hz
Reduced resolution Yes
Current consumption 0 … 2 mA (LOW) | 3 … 10 mA (HIGH)
IP protection class IP67
Ambient Temperature -25 ... +50 °C
Performance level e
Sensor width 27.8 mm
Switching thresholds 11 … 30 V (HIGH) | 0 … 2 V (LOW)
Beam coding available Yes
Tolerance, percentage 10 %
Clock control possible Yes
Load capacity, maximum 2.2 µF
Reaction time, maximum 20 ms
Terminal connection with metal thread
Note (Software Version) as of 2024 Version 1.0
Rated operating current 250 mA
Load inductance, maximum 2 H
Min. Ortam Sıcaklığı -25 °C
Designation, Power supply ML
Maks. Ortam Sıcaklığı +50 °C
Design of control elements OSSD, short-circuit proof, p-type
Designation, Control inputs S1, S2, MSG 1 and MSG 2
Designation, Safety outputs OSSD 1 and OSSD 2
Integral system diagnostics Yes
Leakage current Ir, maximum 1 mA
Nominal Çalışma Voltajı 24 VDC
ACE reference article number 11930047
Contactor control integrated Yes
Test pulse duration, maximum 0.1 ms
Test pulse interval, typical 750 ms
Note (application conditions) Automatic operation, restart inhibit, double confirmation, contactor control, object blanking (non-changeable position and changeable position), alternative beam coding, muting, cycle, multiple sampling
Recommended safety switchgear SRB-E 301
Terminal connector, Recipient Connector plug M12, 12-pole
Wave length of the laserdiode 880 nm
Conduction resistance, maximum 2.5 Ω
Height of the protection field 1,130 mm
Actuation time for manual start 50 … 1500 ms
Classification ZVEI CB24I, Sink C1 | C3 | C2
Height of the Sensor (Receiver) 1,221 mm
Range, protection field, maximum 7 m
Range, protection field, minimum 0.3 m
Rated operating current, Emitter 200 mA
Restart interlock (manual reset) Yes
Terminal, Connector, Transmitter Connector plug M12, 4-pole
Classification ZVEI CB24I, Source C3
Depolama / Taşıma Sıcaklığı -25 ... +75 °C | -25 ... +70 °C
Rated operating current, Receiver 700 mA
Height of the Sensor (Transmitter) 1,211 mm
Integral system diagnostics, status Yes
Number of fail-safe digital outputs 2
Protection class (Operating resource) 3
Radiation emission level to EN 12198-1 Category 0
Length of the connectable cable, maximum 100 m
Safety type in accordance with IEC 61496-1 4
Storage and transport temperature, maximum +70 °C
Storage and transport temperature, minimum -25 °C
Output current, (fail-safe output), maximum 0.25 A
Reaction time of the external devices, maximum 500 ms
Detection ability for test bodies at v = 1.6 m/s 14 mm
Risk group classification of lamp systems to EN 62471 free group
Designation, Contactor controls EDM (Feedback circuits) D_IN
Safety Integrity Level (SIL), suitable for applications in 3

More products in this category

shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3