Schmersal SRB-E-204PE
Order No 103008070
Certificates TÜV cULus CCC
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB-E-204PE Security Relay and Control Modules

Schmersal SRB-E-204PE features -25 ... +60 °C ambient temperature, 115 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×98mm×115mm
  • • Weight: 150 g
  • • Contacts: 8 NC, 4 NO
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 62061
  • • EN IEC 61508

Product Features

  • • Plug-in screw terminals with coding
  • • Input expander module
  • • 1 oder 2-channel control
  • • Monitoring of 4 sensors
  • • 2 Safety outputs
  • • 4 signal outputs

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 2.42 x 10⁻⁵
PFH value 2.66 x 10⁻⁹ /h
Number of LEDs 7
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, hinged guard door, emergency stop button, pull-wire emergency stop switches, safety light curtain
Mission time 20 Year(s)
Gross weight 150 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Clip Tightening Torque 0.5 Nm
Max. cable cross-section 2.5 mm²
Terminal (Mechanical) Removable screw terminals
Operating current 125 mA
Climatic Resistance EN 60068-2-78
Ripple Voltage 10 %
Stop Category 0
Ambient Temperature -25 ... +60 °C
Performance level e
Operating voltage 24 VDC -20% / +20% (PELV power supply unit, I max. 1,0 A, according to EN 60204 (power interruption ≤ 20 ms))
IP Protection (Housing) IP40
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Max. Leakage Current (Ir) 1 mA
Suitable SIL Applications 3
Permitted cable type Single-core rigid / flexible
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 2 A
Overvoltage category III
Electrical Power Consumption 3 W
Rated operating voltage 24 VDC
Number of Signal Outputs 4
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Earth Connection Detection Yes
Removable Terminals Yes
Max. Voltage Drop (Ud) 0.5 V
Rated impulse withstand voltage (Uimp) 0.8 kV
Emergency Release Delay 10 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
DC Min. Rated Control Voltage 19.2 VDC
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Internal operating voltage Ui, module status, error codes
Integrated System Diagnostics Error Code Yes
Max. Switching Frequency (Approx.) 1 Hz
Number of NO (Normally Open) Contacts 4
Release Delay on Power Failure 10 ms
Number of NC (Normally Closed) Contacts 8
Pull-In Delay on Automatic Start 150 ms
Number of Safe Digital Outputs Stop 0 2
shopping_cart