Schmersal SRB-E-212ST
Order No 103007222
Certificates TÜV cULus CCC
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB-E-212ST Security Relay and Control Modules

Schmersal SRB-E-212ST features -25 ... +60 °C ambient temperature, 115 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×98mm×115mm
  • • Weight: 170 g
  • • Contacts: 2 NC, 1 NO
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 62061
  • • EN IEC 61508

Product Features

  • • Plug-in screw terminals with coding
  • • STOP 0 / 1 Function
  • • 1 oder 2-channel control
  • • 2 safety contacts STOP 0
  • • 1 Safety output STOP 1
  • • Drop-out delay adjustable in steps 0 … 30

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 2.42 x 10⁻⁵
PFH value 2.66 x 10⁻⁹ /h
Number of LEDs 6
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, hinged guard door, emergency stop button, pull-wire emergency stop switches, safety light curtain, two-hand control panels
Mission time 20 Year(s)
Gross weight 170 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Clip Tightening Torque 0.5 Nm
Max. cable cross-section 2.5 mm²
Terminal (Mechanical) Removable screw terminals
Ripple Voltage 10 %
Stop Category 0 1
Ambient Temperature -25 ... +60 °C
Performance level e
Reset Edge Detection Yes
Operating voltage 24 VDC -20% / +20% (PELV power supply unit, I max. 1,0 A, according to EN 60204 (power interruption ≤ 20 ms))
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Max. Leakage Current (Ir) 1 mA
Suitable SIL Applications 3
Permitted cable type Single-core rigid / flexible
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 4 A
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 4 A
Overvoltage category III
Electrical Power Consumption 3 W
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 6 A
Earth Connection Detection Yes
Removable Terminals Yes
Max. Voltage Drop (Ud) 0.5 V
Emergency Release Delay 10 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 150 ms
Diagnostic Coverage (DC) Level > 94 %
DC Min. Rated Control Voltage 19.2 VDC
Number of Safety Contacts STOP 0 2
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Internal operating voltage Ui, module status, error codes
Integrated System Diagnostics Error Code Yes
Max. Switching Frequency (Approx.) 0.3 Hz
Number of Signal Outputs STOP 0 1
Number of Signal Outputs STOP 1 1
Number of NO (Normally Open) Contacts 1
Release Delay on Power Failure 10 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 150 ms
Number of Safe Digital Outputs Stop 1 1
Relay Output Impulse Withstand Voltage (Uimp) 4 kV
Semiconductor Output Impulse Withstand Voltage (Uimp) 0.8 kV
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.