SRB-E-301MC
Order No 103014374
Article Code 103014374
Certificates cULus CCC
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB-E-301MC

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×98mm×115mm | Weight: 175 g | Certification: cULus CCC | Contacts: 2 NC | PL e

Standards

  • • EN ISO 13849-1 EN IEC 62061 EN IEC 61508

Product Features

  • • 1 Signalling contact_x000D_
  • • Plug-in screw terminals with coding_x000D_
  • • Suitable for applications up to Cat. 4 / PL e und up to SIL 3_x000D_
  • • 1 or 2 channel signal evaluation_x000D_
  • • Start / feedback circuit monitoring_x000D_
  • • Optionally with short-circuit recognition_x000D_
  • • 3 safety contacts, stop category 0

Technical Specifications

Mounting IEC 60715'e according to standard DIN ray on klipsler
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 4.00 x 10⁻⁴
PFH Value 6.00 x 10⁻⁹ /h
Number of LEDs 5
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Protection system hinged guard door Acil stopping butonu Pull wire acil stopping switch Safety light curtain Safety light bariyerleri
Mission Time 20 Year(s)
Gross Weight 175 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Note (Relative Humidity) Non-condensing
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.5 Nm
Max. Cable Cross-Section 2.5 mm²
Terminal (Mechanical) Removable threaded terminaller
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +65 °C
Performance Level e
Operating Voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Suitable SIL Applications 3
Permissible Cable Type Single core solid / esnek
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.16666666666787933
Current Utilization Cat. DC-13 0.16666666666787933
Number of Auxiliary Contacts 1
Overvoltage Category III
Electrical Power Consumption 5 VA
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.041666666667879326
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Diagnostic Coverage (DC) Level > 99 %
DC Min. Rated Control Voltage 20.4 VDC
Number of Safety Contacts STOP 0 3
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Konum relay K2 Konum relay K1 Internal operation voltage U i UB: Supply voltage open
Max. Switching Frequency (Approx.) 0.3 Hz
Emergency Stop Release Delay (Max.) 10 ms
Release Delay on Power Failure 50 ms
Number of NC (Normally Closed) Contacts 2
Max. Pull-In Delay on Automatic Start 120 ms
shopping_cart