Order No
103014374
Certificates
cULus CCC
Schmersal
Safe Signal Processing
Security Relay and Control Modules
SRB-E-301MC Security Relay and Control Modules
Schmersal SRB-E-301MC features -25 ... +65 °C ambient temperature, 115 mm depth and 22.5 mm width.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×98mm×115mm
- • Weight: 175 g
- • Certification: cULus CCC
- • Contacts: 2 NC
- • PL e
Standards
- • EN ISO 13849-1
- • EN IEC 62061
- • EN IEC 61508
Product Features
- • 1 Signalling contact
- • Plug-in screw terminals with coding
- • Suitable for applications up to Cat. 4 / PL e und up to SIL 3
- • 1 or 2 channel signal evaluation
- • Start / feedback circuit monitoring
- • Optionally with short-circuit recognition
- • 3 safety contacts, stop category 0
Technical Specifications
Mounting
Snaps onto standard DIN rail according to IEC 60715
Depth
115 mm
Category
4
Width
22.5 mm
Height
98 mm
PFD Value
4.00 x 10⁻⁴
PFH value
6.00 x 10⁻⁹ /h
Number of LEDs
5
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor, guard system, hinged guard door, emergency stop button, pull-wire emergency stop switches, safety light curtain, safety light barriers
Mission time
20 Year(s)
Gross weight
175 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
Ag-Ni, self-cleaning, positive drive
Start Input
Yes
Pollution degree
2
Min. cable cross-section
0.25 mm²
Note (Relative Humidity)
Non-condensing
Vibration resistance
10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.5 Nm
Max. cable cross-section
2.5 mm²
Terminal (Mechanical)
Removable screw terminals
Climatic Resistance
EN 60068-2-78
Ripple Voltage
10 %
Stop Category
0
Ambient Temperature
-25 ... +65 °C
Performance level
e
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
3
Permitted cable type
Single-core rigid / flexible
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
4 A
Current Utilization Cat. DC-13
4 A
Number of auxiliary contacts
1
Overvoltage category
III
Electrical Power Consumption
5 VA
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
1 A
Earth Connection Detection
Yes
Removable Terminals
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Rated impulse withstand voltage (Uimp)
4 kV
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
Diagnostic Coverage (DC) Level
> 99 %
DC Min. Rated Control Voltage
20.4 VDC
Number of Safety Contacts STOP 0
3
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Position relay K2 Position relay K1 Internal operating voltage Ui UB: supply voltage on
Max. Switching Frequency (Approx.)
0.3 Hz
Emergency Stop Release Delay (Max.)
10 ms
Release Delay on Power Failure
50 ms
Number of NC (Normally Closed) Contacts
2
Max. Pull-In Delay on Automatic Start
120 ms