Schmersal SRB-E-301MC-CC
Order No 103016932
Certificates cULus CCC
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB-E-301MC-CC Security Relay and Control Modules

Schmersal SRB-E-301MC-CC features -25 ... +65 °C ambient temperature, 115 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×98mm×115mm
  • • Weight: 250 g
  • • Certification: cULus CCC
  • • Contacts: 2 NC
  • • PL e

Standards

  • • EN ISO 13849-1
  • • EN IEC 62061
  • • EN IEC 61508

Product Features

  • • Plug-in spring-cage terminal blocks with coding
  • • 1 Signalling contact
  • • Suitable for applications up to Cat. 4 / PL e und up to SIL 3
  • • 1 or 2 channel signal evaluation
  • • Start / feedback circuit monitoring
  • • Optionally with short-circuit recognition
  • • 3 safety contacts, stop category 0

Technical Specifications

Mounting Snaps onto standard DIN rail according to IEC 60715
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 4.00 x 10⁻⁴
PFH value 6.00 x 10⁻⁹ /h
Number of LEDs 5
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, guard system, hinged guard door, emergency stop button, pull-wire emergency stop switches, safety light curtain, safety light barriers
Mission time 20 Year(s)
Gross weight 250 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Note (Relative Humidity) Non-condensing
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Max. cable cross-section 1.5 mm²
Terminal (Mechanical) Removable cage terminals
Climatic Resistance EN 60068-2-78
Ripple Voltage 10 %
Stop Category 0
Ambient Temperature -25 ... +65 °C
Performance level e
Operating voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Suitable SIL Applications 3
Permitted cable type Single-core rigid / flexible
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 4 A
Current Utilization Cat. DC-13 4 A
Number of auxiliary contacts 1
Overvoltage category III
Electrical Power Consumption 5 VA
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 1 A
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Rated impulse withstand voltage (Uimp) 4 kV
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
Diagnostic Coverage (DC) Level > 99 %
DC Min. Rated Control Voltage 20.4 VDC
Number of Safety Contacts STOP 0 3
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Position relay K2 Position relay K1 Internal operating voltage Ui UB: supply voltage on
Max. Switching Frequency (Approx.) 0.3 Hz
Emergency Stop Release Delay (Max.) 10 ms
Release Delay on Power Failure 50 ms
Number of NC (Normally Closed) Contacts 2
Max. Pull-In Delay on Automatic Start 120 ms
shopping_cart
Quote Cart
shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3