SRB-E-301ST-CC
Order No 103016568
Article Code 103016568
Certificates TÜV cULus CCC
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB-E-301ST-CC

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×98mm×115mm | Weight: 250 g | Contacts: 2 NC, 1 NO | PL e

Standards

  • • EN ISO 13849-1 EN IEC 62061 EN IEC 61508

Product Features

  • • Plug-in spring-cage terminal blocks with coding_x000D_
  • • STOP 0 Function_x000D_
  • • 1 oder 2-channel control_x000D_
  • • Start button / Auto-start_x000D_
  • • 1 Auxiliary contact_x000D_
  • • 3 safety contacts

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 5.30 x 10⁻⁵
PFH Value 1.25 x 10⁻⁸ /h
Number of LEDs 5
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Protection system hinged guard door Acil stopping butonu Pull wire acil stopping switch Safety light curtain Safety light bariyerleri Safety safety mats
Mission Time 20 Year(s)
Gross Weight 250 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.2 mm²
Note (Relative Humidity) Non-condensing
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Max. Cable Cross-Section 1.5 mm²
Terminal (Mechanical) Removable cage terminals
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +60 °C
Performance Level e
Reset Edge Detection Yes
Operating Voltage 24 VAC -15 % / +10 % 24 VDC -20 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Suitable SIL Applications 3
Permissible Cable Type Single core solid / esnek
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.16666666666787933
Current Utilization Cat. DC-13 0.16666666666787933
Number of Auxiliary Contacts 1
Overvoltage Category III
Electrical Power Consumption 7 VA
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.041666666667879326
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Impulse Withstand Voltage (Uimp) 4 kV
Emergency Release Delay 10 ms
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 150 ms
Diagnostic Coverage (DC) Level > 94 %
DC Min. Rated Control Voltage 20.4 VDC
Number of Safety Contacts STOP 0 3
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Internal operating voltage Ui, module status, error codes
Integrated System Diagnostics Error Code Yes
Max. Switching Frequency (Approx.) 0.3 Hz
Number of NO (Normally Open) Contacts 1
Release Delay on Power Failure 10 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 150 ms
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.