SRB-E-302FWS-TS
Order No 103014754
Article Code 103014754
Certificates TÜV cULus CCC
Schmersal Emniyetli Sinyal İşleme Güvenlik Rölesi ve Kontrol Modülleri

SRB-E-302FWS-TS

Product Description

  • • Voltage: 24 VDC | Dimensions: 22.5mm×98mm×115mm | Weight: 170 g | PL e

Standards

  • • EN ISO 13849-1 EN IEC 62061 EN IEC 61508

Product Features

  • • 2 Safety contacts, 1 Safety Output_x000D_
  • • Plug-in screw terminals with coding_x000D_
  • • 1 Signalling output - status safety module_x000D_
  • • 1 Signalling output - failure massage dynamic_x000D_
  • • Detects standstill using 1 or 2 impulse sensors_x000D_
  • • additional standstill signal, e.g. PLC as second input channel_x000D_
  • • 2-channel time monitoring

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 115 mm
Category 4
Width 22.5 mm
Height 98 mm
PFD Value 2.42 x 10⁻⁵
PFH Value 2.66 x 10⁻⁹ /h
Number of LEDs 6
Impact Resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safe durdurma monitoring Fault safe gecikme timer
Mission Time 20 Year(s)
Gross Weight 170 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
Electronic Fuse Yes
Clip Tightening Torque 0.5 Nm
Max. Cable Cross-Section 2.5 mm²
Number of NO Inputs 1
Number of NC Inputs 2
Terminal (Mechanical) Removable threaded terminaller
Operating Current 125 mA
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +60 °C
Performance Level e
Reset Edge Detection Yes
Operating Voltage 24 VDC -20% / +20% (PELV power unit I maks. 1,0 A, EN 60204'e according to (power interruption ≤ 20 ms))
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Max. Leakage Current (Ir) 1 mA
Suitable SIL Applications 3
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 2
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 0.16666666666787933
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 0.16666666666787933
Overvoltage Category III
Electrical Power Consumption 3 W
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
Number of Signal Outputs 2
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.041666666667879326
Earth Connection Detection Yes
Max. Voltage Drop (Ud) 0.5 V
Emergency Release Delay 10 ms
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 150 ms
Diagnostic Coverage (DC) Level > 94 %
DC Min. Rated Control Voltage 19.2 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Internal operating voltage Ui, module status, error codes
Rated Insulation Voltage (Uᵢ) 250 V / 50 V
Max. Switching Frequency (Approx.) 0.3 Hz
Number of Safe Digital Outputs 1
Release Delay on Power Failure 10 ms
Pull-In Delay on Automatic Start 150 ms
Opening Delay on Automatic Start Adjustable
Relay Output Impulse Withstand Voltage (Uimp) 4 kV
Semiconductor Output Impulse Withstand Voltage (Uimp) 0.8 kV