Schmersal SRB100DR
Order No 101186279
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB100DR Security Relay and Control Modules

Schmersal SRB100DR features -25 ... +60 °C ambient temperature, 121 mm depth and 22.5 mm width.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×100mm×121mm
  • • Weight: 250 g
  • • Contacts: 2 NC

Standards

  • • EN IEC 60947-5-1
  • • EN IEC 61508

Product Features

  • • Safety relay module for double reset
  • • Suitable for signal processing of potential-free outputs, e.g. command devices
  • • 1 safety contact, STOP 0

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Depth 121 mm
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
Height 100 mm
Number of LEDs 4
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Mission time 20 Year(s)
Gross weight 250 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. cable cross-section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Terminal (Mechanical) Screw terminals
Climatic Resistance EN 60068-2-78
Ripple Voltage 10 %
Ambient Temperature -25 ... +60 °C
Operating voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Reset When Power is Removed Yes
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Connection Diagram Note The wiring diagram is shown with guard doors closed and in the de-energised condition. Applications: for products such as rotary cam switches.
Permitted cable type Single-core rigid / flexible
Number of safety contacts 1
IP Protection (Mounting Area) IP54
Current Utilization Cat. AC-15 6 A
Current Utilization Cat. DC-13 6 A
Overvoltage category III
Electrical Power Consumption 6 VA
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
Earth Connection Detection Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Rated impulse withstand voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Position relay K2 Position relay K1 Position relay K3
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 2
Pull-In Delay on Automatic Start 100 ms