SRB101EXi-1A
Order No 103037576
Certificates INMETRO ATEX ATEX, IECEx, INMETRO, PESO IECEx
Schmersal Ex / ATEX Anahtarlama Cihazları Emniyet Röle Modülleri (SRB-EXi)

SRB101EXi-1A

SRB101EXi-1A — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +60 °C | -30 ... +60 °C; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715; Width: 22.5 mm. Article number: 103037576. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 265 g
  • • Sertifika: INMETRO ATEX ATEX, IECEx, INMETRO, PESO IECEx

Standards

  • • EN IEC 61508
  • • EN ISO 13849-1
  • • EN IEC 60947-5-1

Product Features

  • • Automatic reset function
  • • Reset with trailing edge
  • • 1 safety contact
  • • Suitable for signal processing of emergency stop control devices, interlocking equipment, etc
  • • Installation in Ex-Zone 2

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 22.5 mm
EMC rating EMC-Directive
Height 100 mm
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type DC
Shock resistance 10 g / 11 ms
Stop-Category 0
Mission time 15 Year(s)
Net Ağırlık 265 g
Number of LEDs 5
Ripple voltage 10 %
Climatic stress EN 60068-2-78
Gross weight 265 g
Category, Stop 0 4
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0. self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VDC -10 % / +20 %
PFH value, Stop 0 2.00 x 10⁻⁸ /h
Vibration resistance 10 ... 55 Hz, Amplitude 0.35 mm
Max. cable cross-section 2.5 mm²
Current consumption 57 mA
Ambient Temperature -25 ... +60 °C | -30 ... +60 °C
Mechanical life (min.) 10,000,000
Utilisation category AC-15 | DC-13
Note (Wiring diagram) Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | The feedback circuit monitors the position of the contactors KA and KB. | To secure a guard door up to PL e and Category 4 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge. | If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a re | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations IEC/EN 60947-1
Cross-circuit detection Yes
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Number of safety contacts 1
Maks. Ortam Sıcaklığı +60 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Explosion protection zones 2
Utilization Category AC-15 2 A | 230 VAC
Utilization Category DC-13 24 VDC | 2 A | 24 VDC / 2 A
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 1
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VDC -15%/+20%, residual ripple max. 10% | 24 VDC
Electrical power consumption 3 W
Explosion protection category 3G
Note (application conditions) Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum 30 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Explosion protection designation D II (2) D [Ex ib Db] IIIC | D II (2) G [Ex ib Gb] IIC | D II 3 G Ex nA nC IIC T5 Gc (Installation SRB, in Zone 2)
Performance Level, stop 0, up to e
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Explosion protection: regulations EN IEC 60079-0 | EN 60079-11 | EN IEC 60079-15
Pull-in delay at RESET, typically 20 ms
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Rated control voltage at DC, maximum 28.8 VDC
Number of NC (Normally Closed) Contacts 2
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
IP Degree of protection of the enclosure IP40
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
IP Degree of protection of clips or terminals IP20
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 20 ms
Drop-out delay in case of "emergency stop", maximum 20 ms
Pull-in delay at automatic start, maximum, typically 300 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in 3

More products in this category