Depth
121 mm
Mounting
Snaps onto standard DIN rail to EN 60715
General note
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width
22.5 mm
EMC rating
EMC-Directive
Height
100 mm
Cable Cross-Section
0.25 mm² ... 2.5 mm²
Voltage type
DC
Shock resistance
10 g / 11 ms
Stop-Category
0
Mission time
15 Year(s)
Net Ağırlık
265 g
Number of LEDs
5
Ripple voltage
10 %
Climatic stress
EN 60068-2-78
Gross weight
265 g
Category, Stop 0
4
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgSn0. self-cleaning, positive drive
Pollution degree
2
Min. cable cross-section
0.25 mm²
Operating voltage
24 VDC -10 % / +20 %
PFH value, Stop 0
2.00 x 10⁻⁸ /h
Vibration resistance
10 ... 55 Hz, Amplitude 0.35 mm
Max. cable cross-section
2.5 mm²
Current consumption
57 mA
Ambient Temperature
-25 ... +60 °C | -30 ... +60 °C
Mechanical life (min.)
10,000,000
Utilisation category
AC-15 | DC-13
Note (Wiring diagram)
Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | The feedback circuit monitors the position of the contactors KA and KB. | To secure a guard door up to PL e and Category 4 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X2. If the feedback circuit is not required, establish a bridge. | If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a re | The wiring diagram is shown with guard doors closed and in de-energised condition.
Terminal designations
IEC/EN 60947-1
Cross-circuit detection
Yes
Wire breakage detection
Yes
Automatic reset function
Yes
Min. Ortam Sıcaklığı
-25 °C
Number of safety contacts
1
Maks. Ortam Sıcaklığı
+60 °C
Note (Contact resistance)
in new state
Earth connection detection
Yes
Explosion protection zones
2
Utilization Category AC-15
2 A | 230 VAC
Utilization Category DC-13
24 VDC | 2 A | 24 VDC / 2 A
Tightening torque of Clips
0.6 Nm
Number of auxiliary contacts
1
Overvoltage category
III | 3
Contact resistance, maximum
0.1 Ω
Nominal Çalışma Voltajı
24 VDC -15%/+20%, residual ripple max. 10% | 24 VDC
Electrical power consumption
3 W
Explosion protection category
3G
Note (application conditions)
Pull-wire emergency stop switches | Emergency-Stop button | Safety sensor | Guard system
Conduction resistance, maximum
30 Ω
Rated impulse withstand voltage (Uimp)
4 kV
Explosion protection designation
D II (2) D [Ex ib Db] IIIC | D II (2) G [Ex ib Gb] IIC | D II 3 G Ex nA nC IIC T5 Gc (Installation SRB, in Zone 2)
Performance Level, stop 0, up to
e
Depolama / Taşıma Sıcaklığı
-40 ... +85 °C
Explosion protection: regulations
EN IEC 60079-0 | EN 60079-11 | EN IEC 60079-15
Pull-in delay at RESET, typically
20 ms
Common Cause Failure (CCF), minimum
65
Integral system diagnostics, status
Yes
Rated control voltage at DC, maximum
28.8 VDC
Number of NC (Normally Closed) Contacts
2
Diagnostic Coverage (DC) Level, Stop 0
≥ 99 %
IP Degree of protection of the enclosure
IP40
Storage and transport temperature, maximum
+85 °C
Storage and transport temperature, minimum
-40 °C
Rated AC voltage for controls at DC minimum
20.4 VDC
IP Degree of protection of clips or terminals
IP20
IP Degree of protection of the installation space
IP54
Drop-out delay in case of power failure, typically
20 ms
Drop-out delay in case of "emergency stop", maximum
20 ms
Pull-in delay at automatic start, maximum, typically
300 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in
3