Order No
101181911
Certificates
cULus CCC
Schmersal
Safe Signal Processing
Security Relay and Control Modules
SRB200X2 Security Relay and Control Modules
Schmersal SRB200X2 features -25 ... +60 °C ambient temperature and 121 mm depth.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×100mm×121mm
- • Weight: 230 g
- • Certification: cULus CCC
- • Contacts: 2 NC
Standards
- • EN IEC 60947-5-1
- • EN IEC 61508
Product Features
- • 2 safety contacts, STOP 0
- • Suitable for the signal processing of outputs with contact sensors
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
SIL Stop 0
3
Height
100 mm
Number of LEDs
3
Shock resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Guard system, emergency stop button, pull-wire emergency stop switches
Mission time
20 Year(s)
Category Stop 0
4
Gross weight
230 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgSn0. self-cleaning, positive drive
Start Input
Yes
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0
≥ 99 %
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-78
Ripple Voltage
10 %
Stop Category
0
Ambient Temperature
-25 ... +60 °C
Reset Edge Detection
Yes
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Connection Diagram Note
The wiring diagram is shown with guard doors closed and in the de-energised condition. The system can be classified even if only one external relay or contactor is used.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
2
IP Protection (Mounting Area)
IP54
Current Utilization Cat. AC-15
6 A
Current Utilization Cat. DC-13
6 A
Performance Level Stop 0
e
Overvoltage category
III
Electrical Power Consumption
3 VA
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
250 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Rated impulse withstand voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Position relay K2 Position relay K1
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Opening Delay on Automatic Start
Adjustable