Order No
101183408
Article Code
101183408
Certificates
cULus TILVA
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Şalterleri
SRB200ZHX1
Product Description
- • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 220 g | Certification: cULus TILVA | Contacts: 2 NO
Standards
- • EN IEC 60947-5-1 EN ISO 13851 EN IEC 61508
Product Features
- • Monitoring two-hand control panels to EN ISO 13851_x000D_
- • 2 güvenlik kontağı, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
SIL Stop 0
3
Height
100 mm
Number of LEDs
3
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Two-hand control panels
Mission Time
20 Year(s)
Category Stop 0
4
Gross Weight
220 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact Material
AgSn0. self-cleaning, positive drive
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
DC Level Stop 0
≥ 99 %
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
Terminal (Mechanical)
Threaded terminal block
Climatic Resistance
EN 60068-2-78
Ripple Voltage
0.1
Stop Category
0
Ambient Temperature
-25 ... +60 °C
Operating Voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Connection Diagram Note
Relay exit 2 channel kontrole is suitable. Automatic start programlanabilir. Kontrol cross short devre and toprak leakages recognizes.
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
2
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.25
Current Utilization Cat. DC-13
0.25
Performance Level Stop 0
e
Overvoltage Category
III
Electrical Power Consumption
1.6 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Impulse Withstand Voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/Transport Temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Konum relay K2 Konum relay K1
Number of NO (Normally Open) Contacts
2
Release Delay on Power Failure
80 ms
Pull-In Delay on Automatic Start
100 ms