Order No
101212555
Certificates
TÜV cULus
Schmersal
Safe Signal Processing
Security Relay and Control Modules
SRB201LC Security Relay and Control Modules
Schmersal SRB201LC features -25 ... +60 °C ambient temperature and 121 mm depth.
Product Description
- • Voltage: 24 VDC
- • Dimensions: 22.5mm×100mm×121mm
- • Weight: 200 g
- • Contacts: 2 NC
Standards
- • EN IEC 60947-5-1
- • EN IEC 61508
Product Features
- • Suitable for the signal processing of outputs with contact sensors
- • 2 safety contacts, STOP 0
- • 1 signal output
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
General note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
SIL Stop 0
3
Height
100 mm
Number of LEDs
3
Shock resistance
10 g / 11 ms
EMC Class
EMC Directive
Application Note
Guard system, emergency stop button, pull-wire emergency stop switches, safety light curtain
Mission time
20 Year(s)
Category Stop 0
4
Gross weight
200 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact material
AgSn0. self-cleaning, positive drive
Pollution degree
2
Min. cable cross-section
0.25 mm²
Vibration resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
DC Level Stop 0
≥ 99 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. cable cross-section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
Terminal (Mechanical)
Screw terminals
Climatic Resistance
EN 60068-2-78
Ripple Voltage
10 %
Stop Category
0 1
Ambient Temperature
-25 ... +60 °C
Operating voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Connection Diagram Note
The wiring diagram is shown with guard doors closed and in the de-energised condition. The relay outputs are suitable for 2-channel control. Automatic start is programmed by connecting terminals X1/X2. Connect the NC contact to S11/S12 and bridge S12/S22.
Permitted cable type
Single-core rigid / flexible
Number of safety contacts
2
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
6 A
Current Utilization Cat. DC-13
6 A
Performance Level Stop 0
e
Overvoltage category
III
Electrical Power Consumption
5.2 VA
Min. Switching Capacity
10 mA
Rated operating voltage
24 VDC
Number of Signal Outputs
1
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
2 A
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Rated impulse withstand voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/transport temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Position relay K2 Position relay K1 Internal operating voltage Ui
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
1