SRB202MSK
Order No 101191928
Schmersal Safe Switching and Monitoring Emniyet Konum Şalterleri (PS Serisi)

SRB202MSK

SRB202MSK — Schmersal product. Key specifications: Housing Material: Glass-fibre reinforced thermoplastic, ventilated; Ambient Temperature: -25 ... +45 °C; Terminal connection: Screw terminals; Depth: 121 mm; Mounting: Snaps onto standard DIN rail to EN 60715. Article number: 101191928. Request a quote for pricing and lead time; technical data and documents are listed below.

Product Description

  • • Ağırlık: 330 g

Standards

  • • EN IEC 60947-5-3
  • • EN IEC 61508
  • • EN IEC 60947-5-5
  • • EN IEC 60947-5-1
  • • EN IEC 60204-1
  • • EN IEC 60947-1
  • • EN ISO 13849-1
  • • EN IEC 62061

Product Features

  • • Muting signalling device monitoring
  • • 2 safety contacts, STOP 0
  • • 2 Signalling outputs

Technical Specifications

Depth 121 mm
Mounting Snaps onto standard DIN rail to EN 60715
General note Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Width 45 mm
EMC rating EMC-Directive
Height 100 mm
Cable Cross-Section 0.25 mm² ... 2.5 mm²
Voltage type DC
Shock resistance 30 g / 11 ms
Stop-Category 0
Mission time 20 Year(s)
Net Ağırlık 330 g
Number of LEDs 8
Ripple voltage 10 %
Climatic stress EN 60068-2-78
Electronic Fuse Yes
Gross weight 330 g
Category, Stop 0 4
Feedback circuit Yes
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0, Ag-Ni, self-cleaning, positive drive
Pollution degree 2
Min. cable cross-section 0.25 mm²
Operating voltage 24 VDC -10 % / +20 %
PFH value, Stop 0 2.00 x 10⁻⁸ /h
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
Max. cable cross-section 2.5 mm²
Ambient Temperature -25 ... +45 °C
Removable Terminals Yes
Mechanical life (min.) 10,000,000
Utilisation category DC-13
Allowed type of cable solid single-wire | flexible
Note (Wiring diagram) The example shows a 2-channel control of 2 muting sensors and an external master reset button. | The wiring diagram is shown with non-actuated muting sensors and in de-energised condition. | (H2) = Feedback circuit | The control recognises cross-short, cable break and earth leakages in the monitoring circuit. | Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. | F1 = Electronic fuse
Terminal designations IEC/EN 60947-1
Terminal connection Screw terminals
Number of inputs for NC 2
Wire breakage detection Yes
Automatic reset function Yes
Min. Ortam Sıcaklığı -25 °C
Note (Delivery capacity) Not available!
Number of safety contacts 2
Maks. Ortam Sıcaklığı +45 °C
Note (Contact resistance) in new state
Earth connection detection Yes
Indicated operating states Position relay K1 | Internal operating voltage Ui | Position relay K3 | Position relay K5 | Position relay K2 | Position of the muting signalling device LA
Utilization Category DC-13 24 VDC | 2 A | 24 VDC / 2 A
Tightening torque of Clips 0.6 Nm
Number of auxiliary contacts 2
Overvoltage category III | 3
Contact resistance, maximum 0.1 Ω
Nominal Çalışma Voltajı 24 VDC -15%/+20%, residual ripple max. 10% | 24 VDC
Electrical power consumption 3.1 W
Number of signalling outputs 2
Note (application conditions) Muting function
Conduction resistance, maximum 40 Ω
Rated impulse withstand voltage (Uimp) 4 kV
Performance Level, stop 0, up to e
Depolama / Taşıma Sıcaklığı -40 ... +85 °C
Number of Safety contacts, STOP 0 2
Common Cause Failure (CCF), minimum 65
Integral system diagnostics, status Yes
Rated control voltage at DC, maximum 28.8 VDC
Diagnostic Coverage (DC) Level, Stop 0 ≥ 99 %
IP Degree of protection of the enclosure IP40
Storage and transport temperature, maximum +85 °C
Storage and transport temperature, minimum -40 °C
Rated AC voltage for controls at DC minimum 20.4 VDC
IP Degree of protection of clips or terminals IP20
IP Degree of protection of the installation space IP54
Drop-out delay in case of power failure, typically 60 ms
Drop-out delay in case of "emergency stop", maximum 20 ms
Pull-in delay at automatic start, maximum, typically 200 ms
Safety Integrity Level (SIL), Stop 0, suitable for applications in 3