Schmersal SRB211AN (V.2)
Order No 101209242
Certificates IFA cULus
Schmersal Safe Signal Processing Security Relay and Control Modules

SRB211AN (V.2) Security Relay and Control Modules

Schmersal SRB211AN (V.2) features -25 ... +60 °C ambient temperature and 121 mm depth.

Product Description

  • • Voltage: 24 VDC
  • • Dimensions: 22.5mm×100mm×121mm
  • • Weight: 250 g
  • • Certification: IFA cULus
  • • Contacts: 1 NC, 1 NO

Standards

  • • EN IEC 60947-5-1
  • • EN IEC 61508

Product Features

  • • STOP 0 / 1 Function
  • • 1 oder 2-channel control
  • • Start button / Auto-start
  • • Drop-out delay 0 … 30

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning Discontinued product
Depth 121 mm
General note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
SIL Stop 0 3
SIL Stop 1 2
Height 100 mm
PFD Value 5.30 x 10⁻⁵
Number of LEDs 6
Shock resistance 30 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor, guard system, emergency stop button, pull-wire emergency stop switches
Mission time 20 Year(s)
Category Stop 0 4
Category Stop 1 3
Gross weight 250 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact material AgSn0, Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution degree 2
Min. cable cross-section 0.25 mm²
Vibration resistance 10...55 Hz, Amplitude 0.35 mm, ± 15 %
DC Level Stop 0 ≥ 99 %
DC Level Stop 1 > 60 %
Electronic Fuse Yes
Frequency Range 50 Hz 60 Hz
Clip Tightening Torque 0.6 Nm
Max. cable cross-section 2.5 mm²
PFH Value Stop 0 2.00 x 10⁻⁸ /h
PFH Value Stop 1 2.00 x 10⁻⁷ /h
Terminal (Mechanical) Screw terminals
Climatic Resistance EN 60068-2-78
Ripple Voltage 10 %
Stop Category 0 1
Ambient Temperature -25 ... +60 °C
Reset Edge Detection Yes
Operating voltage 24 VAC -15 % / +10 % 24 VDC -15 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Cross-Circuit Detection Yes
Spare Part Article Number 101211935
Connection Diagram Note The wiring diagram is shown with guard doors closed and in the de-energised condition. Input level: example of 2-channel control. With external reset button (R).
Permitted cable type Single-core rigid / flexible
Number of safety contacts 3
IP Protection (Mounting Area) IP54
Automatic Reset Function Yes
Current Utilization Cat. AC-15 3 A
Current Utilization Cat. DC-12 0.1 A
Current Utilization Cat. DC-13 2 A
Performance Level Stop 0 e
Performance Level Stop 1 d
Overvoltage category III
Electrical Power Consumption 5.9 VA
Min. Switching Capacity 10 mA
Rated operating voltage 24 VDC
Number of Signal Outputs 1
AC Control Voltage 50Hz min. 20.4 VAC
AC Control Voltage 60Hz min. 20.4 VAC
Voltage Utilization Cat. AC-15 230 VAC
Voltage Utilization Cat. DC-12 24 VDC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 2 A
Earth Connection Detection Yes
Removable Terminals Yes
AC Control Voltage 50Hz max. 26.4 VAC
AC Control Voltage 60Hz max. 26.4 VAC
Rated impulse withstand voltage (Uimp) 4 kV
Emergency Release Delay 30 ms
Storage/transport temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
Number of Safety Contacts STOP 0 3
Number of Safety Contacts STOP 1 2
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Position relay K2 Position relay K1 Internal operating voltage Ui Position relay K3/K4
Number of NO (Normally Open) Contacts 1
Release Delay on Power Failure 80 ms
Number of NC (Normally Closed) Contacts 1
Pull-In Delay on Automatic Start 250 ms